Vibration; Esd Strength; Main Technical Specifications; Maximum Ratings - Nokia NSB-7 Series Service Manual

Transceivers
Table of Contents

Advertisement

NSB-7
System Module
might cause malfunction momentary. Long term wetness will cause permanent
damage (corrosion etc.).

Vibration

All requirements must be met in following vibration conditions:
Freq.
10...100 Hz
100...500 Hz

ESD Strength

Module should withstand an electrostatic discharge from 150 pF capacitor
via 300 ohm resistor. Conducted discharge into antenna and battery connector
is 8 kV (>10 discharges) and air contact 15 kV (>10 discharges).

Main Technical Specifications

Maximum Ratings

Parameter
Normal battery voltage, idle mode
Regulated supply voltage
Voltage reference
Operating temperature range
Absolute maximum voltage
Software cut-off voltage
Page 44
ASD (Acceleration Spectral Density) random vibration
2
3
2
3 m
/s
(0.0132 g
/Hz)
-3 dB/Octave
Rating
3.6 V
2.8 +/- 3% V
1.5 +/- 1.5% V
-10...+55 deg. C
5.1 V
3.1 V
ãNokia Mobile Phones Ltd.
PAMS Technical Documentation
Issue 1 06/00