AFC edit box (ALT+F):
This selection allows user manually tune the 26 MHz clock. Limits are -1023...-1024
Apply button (ALT+A):
Accepts entered values and validates them. After validation application sends
corresponding messages to ME. Closes dialog and updates Info Window.
Note! Active Unit and Operation mode are not send with because they are activated
immediately.
Set Defaults button (ALT+S):
Sets current values as default Rf Controls values.
Get Defaults button (ALT+U):
Gets default Rf Controls values as current values.
The next automatic selection is made when Quick testing function is ended:
Active Unit = RX
Update RF Information window
The next table shows the dialog's properties on different situations:
ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
TX Power Level: Updated
Continuous Mode Channel: Greyed
Channel: Updated
OPERATION MODE = CONT.:
TX Power Level: OFF, Greyed