Rx Calibration - Nokia NSB-7 Series Service Manual

Transceivers
Table of Contents

Advertisement

NSB-7
Service Software Instructions
RX Calibration... command
Activation
Alt, T, R
Starts RX calibration.
The next automatic selections are made when this tuning function is activated:
• Phone is set to local mode
• Update RF information window
The measurement is started automatically when RX calibration is entered. The measure-
ment is done in five steps:
1. User is requested to put signal generator to high input level (read from.INI file).
2. Measurement with high input level is executed
3. User is requested to put signal generator to low input level (read from.INI file).
4. Measurement with low input level is executed
5. The RX Calibration dialog will be updated when previous steps are done.
Page 32
Status Bar Text
Open RX Calibration dialog box
ãNokia Mobile Phones Ltd.
PAMS Technical Documentation
Issue 1 06/00