NuVinci enviolo CT Assembly Instruction Manual page 41

Table of Contents

Advertisement

Quick Start Guide
AUTOMATiQ
3. Calibration continued
A
B
enviolo Assembly Instruction
[A] enviolo AUTOMATiQ calibration - Bosch Intuvia
When
After enviolo AUTOMATiQ assembly;
After firmware update;
When system functions are not appropriate.
How to - for Intuvia
Turn on the Bosch Intuvia system. Select no motor assist
Activate the "configuration mode" through simultaneous
push and hold of [RESET] and [i] buttons (A).
Push the [i] button, until you can see "gear calibration" on
the screen.
Lift up the rear wheel and pedal fast and easy.
While pedaling, press the "Light" button (B) to start calibration
Continue to pedal while the system shifts from full overdrive to
full underdrive several times to complete the calibration process.
After completion of the calibration process, the system returns
to the ride mode automatically.
[B] enviolo AUTOMATiQ calibration - Bosch Nyon
When
After enviolo AUTOMATiQ assembly;
After firmware update;
When system functions are not appropriate.
How to - for Nyon
Turn on the Bosch Nyon system. Select no motor assist.
Enter the menu by moving the joystick to the left.
Select "Settings" and confirm by pressing the joystick.
Select "My eBike" and confirm by pressing the joystick.
Select "eShift (NuVinci)" and confirm by pressing the joystick.
Select "Gear calibration" and confirm by pressing the joystick.
Lift up the rear wheel and pedal fast and easy.
While pedaling, select "Continue" by pressing the joystick to start
the calibration.
Continue to pedal while the system shifts from full overdrive to full
underdrive several times to complete the calibration process and
the screen indicates "Gear calibration successful".
After completion of the calibration process exit the menu.
41