3. Calibration
On the first set up or after system maintenance or incorrect
functionality the system has to be calibrated.
[D] ENVIOLO CO CONTROLLER
1. Turn system power on. Select no motor assist.
2. Pedal the bicycle lightly through the entire calibration process
(preferable on a stand with the rear wheel off the ground).
3.
On the enviolo CO controller (1), press and hold
the center button for 3 seconds until the rear hub
begins shifting (5-7 seconds) and then release the
button.
4. Continue to pedal lightly through the entire calibration
procedure, while the system shifts from "low" to "high" ratio
multiple times and completes the calibration.
5. Calibration shall not take longer than 12 seconds.
[E] ENVIOLO CA CONTROLLER
1. Turn system power on. Select no motor assist.
2.
On the enviolo CA controller (1), press and hold up and down
button simultanously for 3 seconds until the rear hub begins
shifting (5-7 seconds) and then release the button. While the
calibration is active, the LED will flash white.
3. Pedal the bicycle lightly through the entire calibration
procedure (preferable on a stand with the rear wheel off the
ground), while the system shifts from "low" to "high" ratio
multiple times and completes the calibration.
4. Once calibration is successful the CA controller lights
continously blue for 5 seconds. In case the calibration is
unsuccessful the CA controller lights continously red for 5
seconds. Please retry the calibration.
5. Calibration shall not take longer than 12 seconds.
[F] ENVIOLO SP CONTROLLER
1. Turn system power on, Select no motor assist.
2. On the enviolo SP controller (F) press and hold mode and
down buttons simultanously for 3 seconds until the rear hub
begins shifting (5-7 seconds) and then release the buttons.
While the calibration is active, the LED will flash blue.
3. Pedal the bicycle lightly through the entire calibration
procedure (preferable on a stand with the rear wheel off the
ground), while the system shifts from "low" to "high" ratio multiple
times and completes the calibration.
4. Once calibration is successful the SP controller lights continously
blue for 5 seconds. In case the calibration is unsuccessful the SP
controller lights continously red for 10 seconds. Please retry the calibration.
5. Calibration shall not take longer than 12 seconds.