Proceq ZDR 6020 Instruction Manual page 44

Dynamic retroreflectometer rl
Table of Contents

Advertisement

No. of Markings Filter
Number of expected markings, value taken from the current Marking Preset, see
chapter 5.8.1 on page 37. Default = 1
DayContrastFilter
Calculation of day contrast ratio.
• DayContrast:
• ToleranceBandFromB.: Tolerance band in %, default = 10
Contrast Filter
Calculation of day contrast ratio.
• Contrast Threshold:
• Contrast Threshold.:
OffsetDifferenceFilter
Internal filter, do not change
AverageFilterSettings
Filter settings for average calculation of R
• PercentPassedMin.:
• CutFromTopForMean%: Percentage of the highest measurements to be
• TakeForMeanFromTop%: Percentage of measurements (counted from top) to
• RemovePeaksForMinMax: Enable / disable removal of peaks
CamTrigger
Filter settings for automatic camera triggering. Values taken from the current
Marking Preset, see chapter 5.8.1 on page 37.
• EnableAutoCamTrigger: Enable / disable filter
• CamTriggerMin:
• CamTriggerMax:
Msre & RT Monitor
Important system parameters like lamp voltage, signal quality and vehicle speed are
shown. Click on the "Msre & RT Monitor" tab in the system configuration window:
Enable / disable filter
Enable / disable filter
Contrast threshold, default = 2
(R
L
L
Min percentage of measurements within an interval
that must have passed all filters, default = 10
eliminated (noise reduction), default = 2
be included in average calculation, default = 20
Takes a picture if R
Takes a picture if R
Page 44
DB).
is lower, default = 100
L
is higher, default = 1000
L