3.2 Shipment ...................... 9 3.3 Standard delivery ..................10 3.4 Shoulder bag ....................11 3.5 Options with modification of the ZRS 6060 (built-in) ........11 3.6 Options without modification of the ZRS 6060 ..........11 4 Device overview ....................13 4.1 Adjustable display inclination ..............
Page 3
8.7 Interval timer measurements ............... 27 8.8 Edit, delete and store measurements ............28 9 Quickstart menu ....................29 10 Options ......................29 10.1 Illumination adapters ................. 29 10.2 Handles ..................... 30 10.2.1 Mounting of the handles ..............30 10.2.2 Dismounting ..................33 10.3 Camera......................
Page 4
15.3 Status message “Please calibrate 0.2°” ............ 57 15.4 Error message “Calibration is not OK” ............58 15.5 Error message “Factory calibration has expired” ........58 15.6 Reset of ZRS 6060 ................... 59 16 Maintenance and cleaning ................59 16.1 Maintenance carried out by the user............59 16.2 Cleaning ....................
Illustrations, descriptions as well as the technical specifications conform to the instruction manual on hand at the time of publishing or printing. However, Proceq SA policy is one of continuous product development. All changes resulting from technical progress, modified construction or similar are reserved without obligation for Proceq SA to update.
Description of device The ZRS 6060 is an ergonomic retroreflectometer for determination of night visibility and R’) of traffic signs, safety garments and other (coefficient of retroreflection R reflective materials with measurement of three different observation angles at the same time.
It is strictly forbidden to open the housing of the ZRS 6060! If not observed, all guarantee and liability claims to Proceq SA will be void. The ZRS 6060 is a high quality, state of the art instrument and is safe to operate. Nevertheless, risks may occur during improper use.
7 days. However, this period may vary depending on the courier. Hence, it is recommended to check the exact time limit when receiving the goods. If there are any damages also inform your authorized Proceq agent or Proceq SA immediately. 3.2 Shipment Should the device be transported again, it must be packaged properly.
3.3 Standard delivery The following parts are included in the delivery: 1 Retroreflectometer 1 calibration standard / front plate 1 battery charger (100 – 240V, 50-60 Hz) 1 mapping and data analysis software „MappingTools“ 1 USB-cable for data transfer to computer 1 certificate of manufacturer 1 certificate of calibration 1 shoulder strap...
The shoulder bag is at the same time an optimal storage case for the ZRS 6060. The calibration standard / front plate always has to be mounted on the ZRS 6060 before stowing it in the shoulder bag.
Page 12
(entrance) angle 45° voltage converter DC/AC 12V/230V to be plugged into the cigarette lighter Proceq SA refuses all warranty and liability claims for damages caused by usage of the ZRS 6060 in combination with non-original accessories, or accessories from 3 party suppliers.
(16) Adjusting screw for display inclination resistance of touchscreen 4.1 Adjustable display inclination The ZRS 6060 is equipped with an adjustable display inclination. This ensures an optimal visibility of the display in all conditions. Pull the upper part of the display ahead until you reach the optimal angle. The display inclination can be adjusted seamlessly between the standard vertical position and the maximum tilted position.
Page 16
Quick start menu (17) Enlarged view icon (18) Overview icon (19) Main window icon (20) Average mode is activated (21) Colour identification of measuring sample determined atomatically (22) Observation angle (23) Single values of observation angle (24) Average value of observation angle (25) Temperature and relative humidity (26)
If the battery was completely empty or the unit was not used for a longer period, it takes about 30 seconds to boot up, as the ZRS 6060 was shut off completely. To shut off the unit completely, press the on/off button for at least 8 seconds.
Calibrate 7.1 Front plate with calibration standard The front plate with calibration standard should always be mounted on the ZRS 6060. For measurements, it must be mounted in the measuring position, for calibration in the calibration position. Mounted in the Removing calibration standard, Mounted in the Measuring position...
Always protect the calibration standard from dust, moisture and other environmental factors, keep it mounted on the ZRS 6060 and store the instrument in its shoulder bag. 7.2 Cleaning of the calibration standard The calibration standard can be cleaned using standard window cleaner and a soft cloth.
Page 20
Should the calibration still not be OK after trying several times and despite cleaning the calibration standard and the optical window, it might be necessary to send the instrument to the manufacturer for maintenance and calibration. Please contact Proceq or your authorized Proceq agent. Page 20...
The front plate has to latch audibly. 7.4 Calibration on second calibration standard It is possible to calibrate the ZRS 6060 on a second calibration standard. (e.g. prescribed by the company or authority)
Page 22
Here you can see and change the calibration setup settings of the chosen observation angle. Tap on the row „Calibrate on“ to select the standard onto which the chosen observation angle will be calibrated. Tap the corresponding row to select the second calibration standard.
Page 23
Here the value of the second standard can be inserted. This might be a known reference value of an internal sample or a value measured by an official institute. After the input has been confirmed by tapping „OK“, the menu item „calibration settings“...
According to standard, choose the appropriate version from the table. Measurements of contour markings of heavy and long vehicles and their trailers. According to standard, choose the appropriate version of the ZRS 6060 from the table. Page 24...
8.3 Preparation and safety precautions The standard delivery includes a shoulder strap. When you are not carrying the ZRS 6060 in the shoulder bag, we recommend using the shoulder strap. Secure the ZRS 6060 by connecting the safety clip of the shoulder strap to the suspension clip on the handle of the ZRS 6060.
In the main view, the measurement values will be shown next to each observation angle after a successful reading. To edit or delete a measurement, refer to chapter 8.8 “Edit, delete and store measurements” on page 28. Using the default settings, the measuring values appear in white.
Tap on the symbols , then select “measuring mode” to activate the „pass/fail“ function. Minimum requirements for the retroreflective material to be measured can be defined for each observation angle by setting a lower reference value. If the minimum requirements are fulfilled (pass , the measuring values appear in green.
8.8 Edit, delete and store measurements Tip on the corresponding row to e.g. delete a measurement. An editing window appears and the measurements can be edited, deleted or saved. Deleting several measurements at the same time is possible in the archive, see chapter 11 “Archive” as from page 39 via „Jobs“...
For further information please refer to chapter 11 “Archive” as from page 39. Connect the ZRS 6060 with an external printer e.g. the portable USB- printer. Press the desired measurement to print out the test report. If no measurement is selected the last one will be printed. The default settings which information will be included in the measuring report can be changed in the menu as described in chapter 13.6.8 “Printer”...
The mounting and removal of the optional illumination adapter is always the same procedure independent on which model you choose. Mounting and removal Removal and mounting Mounted of front plate with of illumination adapters illumination adapter calibration standard The used illumination angle is always shown in the display of the main view and this information is stored to each measurement.
Page 31
Extendable handle from 2.2 m to 4 m (86.6” – 157.5”) (33) (34) (40) (39) (37) (35) (38) (36) (33) Fork (34) Handle (35) Remote measuring button (36) Strain relief with safety clip (37) Remote connection (38) Fixing screw (39) Extension button (40) Fork release button...
Page 32
Pull on the fixing screw (38), so that the tip of the screw is behind the support. • Pull back the screws on both sides and slide the fork over the ZRS 6060. Afterwards tighten the screws on both sides.
• Secure the ZRS 6060 by connecting the strain relief with safety clip (36) to the ZRS 6060. • Now remove the protective cover of the ZRS 6060 connection socket by pulling on the cover string. • Plug the remote connection (37) into the connection socket of the ZRS 6060.
(40) before disconnecting. 10.3 Camera The ZRS 6060 can be equipped with a 5-megapixel camera providing additional information on the measurement. The camera is installed on the top of the ZRS 6060.
The signal quality is very good. The quality of the GPS Signal basically indicates how many satellites are used to determine the position of the ZRS 6060. Better signal quality means more precision of the coordinates. The GPS status indication is related to the HDOP (Horizontal Dilution of Precision).
Page 36
After switching on the ZRS 6060, connecting the WAAS GPS unit can take up to 15 minutes until the unit is receiving coordinates. Ensure clear view to the sky to receive good signals. Press to see the GPS-coordinates. By triggering a measurement the GPS-coordinates will be stored in the archive.
10.5.2 Barcode measurements Before triggering a measurement the barcode needs to be read. Switch on the ZRS 6060 and place it closely to the barcode and lift it up and down until the barcode is recognised by the barcode reader.
The recognition of the barcode is confirmed with a short beep and the barcode is displayed in the main view and overview. Trigger a measurement. After the measurement or measurement series is completed, the barcode will no longer be stored and will not be displayed for the next measurement.
11 Archive All stored files are located in the archive. Press to get to the archive. The measurements can be edited, deleted, exported to a USB flash drive or printed out here. 11.1 Sorting of the measurements Here the measurements can be sorted according to the following criteria: •...
11.2 Overview measurements (sorted) The first column shows the observation angles and the second column the respective measuring values. The colour of the retroreflective material, date, time, and in the case of average measurements the number of single measurements e.g. (5), as well as the job are listed in the third column.
„Edit“. Press for the number keyboard. Press for the special signs keyboard. Press for the standard keyboard. 11.5 Printing of a measuring report Connect the ZRS 6060 with an external printer e.g. our optional portable USB-printer Page 41...
Press to print out the current test report. The default settings about which information will be included in the test report can be changed in the menu as described in chapter 13.6.8 “Printer” on page 53. 11.6 Storing the measuring data on USB flash drive Connect a USB-flash drive to the USB-interface (host).
Client USB-interface (type B mini) for connection to a computer. 12.2 PC Mode Connect the ZRS 6060 with a USB-cable to a computer. On the touchscreen of the ZRS 6060 the message „PC Mode” will be displayed. After the instrument has been recognized, it will appear as a drive in Windows Explorer, similar to the picture on the left.
The mapping browser can be deactivated as described in the separate instruction manual MappingTools. If the ZRS 6060 is equipped with the optional WAAS GPS-module and there was a valid signal during the measurements, then they will be displayed in the mapping browser.
13.2 Navigation in the menu Press to get to the menu where several settings can be set. On the top of each window you can read in which menu you are. Navigate in the menu as described in chapter 6 “Navigation”...
and select „Measure mode“ to Press activate average readings. A faster way is to press the symbol in the main window. If the symbol is shown, the average reading is activated. 13.3.3 Pass/Fail and select „Measure mode“ to Press activate the pass/fail function. Minimum reference value for a specimen of retroreflective material (e.g.
If the interval timer is activated, the current setting for the interval time and interval counts can be seen. To change these settings, press on the respective row. The interval time can be set between 5 and 1000 seconds. The interval counts can be set between 2 and 500. 13.5 Jobs and select „Jobs“...
Press required language. If a wrong language was selected and you are not able to get back to the language setup, switch off the ZRS 6060 by pressing the on/off button long. Press the measuring button continuously during switching on to get directly to the language settings.
13.6.3 Date and time select „Setup“ to set date and time. Press 13.6.4 Power and select „Setup“ to change „auto Press off time“. At low battery status, the indicated time is reduced automatically A time period between 2 and 120 minutes can be chosen.
and select „Setup“ to open the menu Press item „Database“. Here you can create a new database, open, rename or delete an existing database and export a database. Tip on the required row. Sometimes it is helpful to store all measurements for a specific project in a new database.
13.6.8 Printer and select „Setup“ to open the menu Press item „Printer“. In this menu you can set which information will be included in the test report printed by a USB printer. Top list Middle list Bottom list 13.6.9 Calibration After expiry of the selected calibration interval, the ZRS 6060 will remind you that a calibration is due.
and select „Setup“ to select the units Press for temperature and length. You can choose between Celsius (°C) and Fahrenheit (°F), and between meters and miles respectively. 13.6.11 Display and select „Setup“ to open this Press menu item. Zehntner calibrates the touchscreen. However, in the course of time the precision of the touchscreen may abate.
and select „Setup“ to reset the Press equipment to factory settings. The reset to factory default cannot be undone. If you are sure to carry out the reset to the factory default you need to confirm the message with „Yes”. 13.7 Diagnostics and select „Setup“...
In order to prevent damage to the battery, the instrument switches off automatically before the battery is completely drained. The ZRS 6060 announces this by displaying the symbol and a message.
The battery may only be replaced by Proceq or by an authorized Proceq agent. If the unit hasn´t been used for a longer period of time, e.g. several months, it should be charged before using.
Contact Proceq or your authorized Proceq agent for returning the unit. 15.6 Reset of ZRS 6060 If the firmware of the ZRS 6060 freezes, reset the instrument by shutting it off completely by pressing the on/off button long.
Please store the instrument including its accessories in the shoulder bag. Make sure that the ZRS 6060 is turned off and unplugged from the battery charger before maintenance. During cleaning take care that under no circumstances cleaning liquid flows into the interior of the instrument.
Page 61
16.3 Adjustment of display inclination resistance he force needed to tilt the display can be adjusted. We recommend using a plastic tool for fixing the screw in order to avoid scratches. Another possibility would be to use a coin e.g. the EUR 1.00 or 2.00 coin.
Page 62
Ø 25 mm (0.98“) Measuring area: Measuring sensor: adapted to V () 0 - 2‘000 cd⋅lx ⋅m Measuring range: Measuring period: approx. 3 seconds 1 GB SD flash memory, about 1‘000‘000 measurements Memory: without pictures or about 1‘000 up to 10‘000 with pictures, depending on picture resolution Interface: Host USB (type A), Client Mini USB (type B)
Page 63
Glossary Accumulator Calibration ....... 19, 54 Capacity ....... 52, 57 Calibration standard ....20 Changing ........58 Factory calibration ...... 60 Charging ........58 Last calibration ......56 Charging cycle ......57 On second calibration standard . 22 Status indication ......57 Calibration standard .......