Proceq ZRS 6060 Instruction Manual

Proceq ZRS 6060 Instruction Manual

Retroreflectometer
Table of Contents

Advertisement

ZRS 6060
Retroreflectometer
Firmware as from v.1.0
Instruction manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZRS 6060 and is the answer not in the manual?

Questions and answers

Summary of Contents for Proceq ZRS 6060

  • Page 1 ZRS 6060 Retroreflectometer Firmware as from v.1.0 Instruction manual...
  • Page 2: Table Of Contents

    3.2 Shipment ...................... 9 3.3 Standard delivery ..................10 3.4 Shoulder bag ....................11 3.5 Options with modification of the ZRS 6060 (built-in) ........11 3.6 Options without modification of the ZRS 6060 ..........11 4 Device overview ....................13 4.1 Adjustable display inclination ..............
  • Page 3 8.7 Interval timer measurements ............... 27 8.8 Edit, delete and store measurements ............28 9 Quickstart menu ....................29 10 Options ......................29 10.1 Illumination adapters ................. 29 10.2 Handles ..................... 30 10.2.1 Mounting of the handles ..............30 10.2.2 Dismounting ..................33 10.3 Camera......................
  • Page 4 15.3 Status message “Please calibrate 0.2°” ............ 57 15.4 Error message “Calibration is not OK” ............58 15.5 Error message “Factory calibration has expired” ........58 15.6 Reset of ZRS 6060 ................... 59 16 Maintenance and cleaning ................59 16.1 Maintenance carried out by the user............59 16.2 Cleaning ....................
  • Page 5 16.3 Adjustment of display inclination resistance ..........61 17 Technical specifications ..................61 Glossary ........................63 Page 5...
  • Page 6: Exclusion Of Liability

    Illustrations, descriptions as well as the technical specifications conform to the instruction manual on hand at the time of publishing or printing. However, Proceq SA policy is one of continuous product development. All changes resulting from technical progress, modified construction or similar are reserved without obligation for Proceq SA to update.
  • Page 7: Description Of Device

    Description of device The ZRS 6060 is an ergonomic retroreflectometer for determination of night visibility and R’) of traffic signs, safety garments and other (coefficient of retroreflection R reflective materials with measurement of three different observation angles at the same time.
  • Page 8: Safety Information

    It is strictly forbidden to open the housing of the ZRS 6060! If not observed, all guarantee and liability claims to Proceq SA will be void. The ZRS 6060 is a high quality, state of the art instrument and is safe to operate. Nevertheless, risks may occur during improper use.
  • Page 9: Delivery Of Device

    7 days. However, this period may vary depending on the courier. Hence, it is recommended to check the exact time limit when receiving the goods. If there are any damages also inform your authorized Proceq agent or Proceq SA immediately. 3.2 Shipment Should the device be transported again, it must be packaged properly.
  • Page 10: Standard Delivery

    3.3 Standard delivery The following parts are included in the delivery: 1 Retroreflectometer 1 calibration standard / front plate 1 battery charger (100 – 240V, 50-60 Hz) 1 mapping and data analysis software „MappingTools“ 1 USB-cable for data transfer to computer 1 certificate of manufacturer 1 certificate of calibration 1 shoulder strap...
  • Page 11: Shoulder Bag

    The shoulder bag is at the same time an optimal storage case for the ZRS 6060. The calibration standard / front plate always has to be mounted on the ZRS 6060 before stowing it in the shoulder bag.
  • Page 12 (entrance) angle 45° voltage converter DC/AC 12V/230V to be plugged into the cigarette lighter Proceq SA refuses all warranty and liability claims for damages caused by usage of the ZRS 6060 in combination with non-original accessories, or accessories from 3 party suppliers.
  • Page 13: Device Overview

    Device overview (11) (14) (10) (10) (14) (16) (13) (12) (15) Page 13...
  • Page 14: Adjustable Display Inclination

    (16) Adjusting screw for display inclination resistance of touchscreen 4.1 Adjustable display inclination The ZRS 6060 is equipped with an adjustable display inclination. This ensures an optimal visibility of the display in all conditions. Pull the upper part of the display ahead until you reach the optimal angle. The display inclination can be adjusted seamlessly between the standard vertical position and the maximum tilted position.
  • Page 15 Main window Enlarged view Overview (17) (18) (19) (17) (18) (19) (23) (22) (23) (21) (28) (21) (25) (26) (27) (31) Display view in average mode Main window Enlarged view Overview (20) (20) (20) (30) (30) (28) (28) (21) (29) Page 15...
  • Page 16 Quick start menu (17) Enlarged view icon (18) Overview icon (19) Main window icon (20) Average mode is activated (21) Colour identification of measuring sample determined atomatically (22) Observation angle (23) Single values of observation angle (24) Average value of observation angle (25) Temperature and relative humidity (26)
  • Page 17: Setting Up

    If the battery was completely empty or the unit was not used for a longer period, it takes about 30 seconds to boot up, as the ZRS 6060 was shut off completely. To shut off the unit completely, press the on/off button for at least 8 seconds.
  • Page 18: Calibrate

    Calibrate 7.1 Front plate with calibration standard The front plate with calibration standard should always be mounted on the ZRS 6060. For measurements, it must be mounted in the measuring position, for calibration in the calibration position. Mounted in the Removing calibration standard, Mounted in the Measuring position...
  • Page 19: Cleaning Of The Calibration Standard

    Always protect the calibration standard from dust, moisture and other environmental factors, keep it mounted on the ZRS 6060 and store the instrument in its shoulder bag. 7.2 Cleaning of the calibration standard The calibration standard can be cleaned using standard window cleaner and a soft cloth.
  • Page 20 Should the calibration still not be OK after trying several times and despite cleaning the calibration standard and the optical window, it might be necessary to send the instrument to the manufacturer for maintenance and calibration. Please contact Proceq or your authorized Proceq agent. Page 20...
  • Page 21: Calibration On Second Calibration Standard

    The front plate has to latch audibly. 7.4 Calibration on second calibration standard It is possible to calibrate the ZRS 6060 on a second calibration standard. (e.g. prescribed by the company or authority)
  • Page 22 Here you can see and change the calibration setup settings of the chosen observation angle. Tap on the row „Calibrate on“ to select the standard onto which the chosen observation angle will be calibrated. Tap the corresponding row to select the second calibration standard.
  • Page 23 Here the value of the second standard can be inserted. This might be a known reference value of an internal sample or a value measured by an official institute. After the input has been confirmed by tapping „OK“, the menu item „calibration settings“...
  • Page 24: Measure

    According to standard, choose the appropriate version from the table. Measurements of contour markings of heavy and long vehicles and their trailers. According to standard, choose the appropriate version of the ZRS 6060 from the table. Page 24...
  • Page 25: Preparation And Safety Precautions

    8.3 Preparation and safety precautions The standard delivery includes a shoulder strap. When you are not carrying the ZRS 6060 in the shoulder bag, we recommend using the shoulder strap. Secure the ZRS 6060 by connecting the safety clip of the shoulder strap to the suspension clip on the handle of the ZRS 6060.
  • Page 26: Average Measurements

    In the main view, the measurement values will be shown next to each observation angle after a successful reading. To edit or delete a measurement, refer to chapter 8.8 “Edit, delete and store measurements” on page 28. Using the default settings, the measuring values appear in white.
  • Page 27: Interval Timer Measurements

    Tap on the symbols , then select “measuring mode” to activate the „pass/fail“ function. Minimum requirements for the retroreflective material to be measured can be defined for each observation angle by setting a lower reference value. If the minimum requirements are fulfilled (pass , the measuring values appear in green.
  • Page 28: Edit, Delete And Store Measurements

    8.8 Edit, delete and store measurements Tip on the corresponding row to e.g. delete a measurement. An editing window appears and the measurements can be edited, deleted or saved. Deleting several measurements at the same time is possible in the archive, see chapter 11 “Archive” as from page 39 via „Jobs“...
  • Page 29: Quickstart Menu

    For further information please refer to chapter 11 “Archive” as from page 39. Connect the ZRS 6060 with an external printer e.g. the portable USB- printer. Press the desired measurement to print out the test report. If no measurement is selected the last one will be printed. The default settings which information will be included in the measuring report can be changed in the menu as described in chapter 13.6.8 “Printer”...
  • Page 30: Handles

    The mounting and removal of the optional illumination adapter is always the same procedure independent on which model you choose. Mounting and removal Removal and mounting Mounted of front plate with of illumination adapters illumination adapter calibration standard The used illumination angle is always shown in the display of the main view and this information is stored to each measurement.
  • Page 31 Extendable handle from 2.2 m to 4 m (86.6” – 157.5”) (33) (34) (40) (39) (37) (35) (38) (36) (33) Fork (34) Handle (35) Remote measuring button (36) Strain relief with safety clip (37) Remote connection (38) Fixing screw (39) Extension button (40) Fork release button...
  • Page 32 Pull on the fixing screw (38), so that the tip of the screw is behind the support. • Pull back the screws on both sides and slide the fork over the ZRS 6060. Afterwards tighten the screws on both sides.
  • Page 33: Dismounting

    • Secure the ZRS 6060 by connecting the strain relief with safety clip (36) to the ZRS 6060. • Now remove the protective cover of the ZRS 6060 connection socket by pulling on the cover string. • Plug the remote connection (37) into the connection socket of the ZRS 6060.
  • Page 34: Camera

    (40) before disconnecting. 10.3 Camera The ZRS 6060 can be equipped with a 5-megapixel camera providing additional information on the measurement. The camera is installed on the top of the ZRS 6060.
  • Page 35: Waas Gps-Unit

    The signal quality is very good. The quality of the GPS Signal basically indicates how many satellites are used to determine the position of the ZRS 6060. Better signal quality means more precision of the coordinates. The GPS status indication is related to the HDOP (Horizontal Dilution of Precision).
  • Page 36 After switching on the ZRS 6060, connecting the WAAS GPS unit can take up to 15 minutes until the unit is receiving coordinates. Ensure clear view to the sky to receive good signals. Press to see the GPS-coordinates. By triggering a measurement the GPS-coordinates will be stored in the archive.
  • Page 37: Barcode Reader And Qr Barcode Reader

    10.5.2 Barcode measurements Before triggering a measurement the barcode needs to be read. Switch on the ZRS 6060 and place it closely to the barcode and lift it up and down until the barcode is recognised by the barcode reader.
  • Page 38: Qr Barcode Measurements

    The recognition of the barcode is confirmed with a short beep and the barcode is displayed in the main view and overview. Trigger a measurement. After the measurement or measurement series is completed, the barcode will no longer be stored and will not be displayed for the next measurement.
  • Page 39: Archive

    11 Archive All stored files are located in the archive. Press to get to the archive. The measurements can be edited, deleted, exported to a USB flash drive or printed out here. 11.1 Sorting of the measurements Here the measurements can be sorted according to the following criteria: •...
  • Page 40: Overview Measurements (Sorted)

    11.2 Overview measurements (sorted) The first column shows the observation angles and the second column the respective measuring values. The colour of the retroreflective material, date, time, and in the case of average measurements the number of single measurements e.g. (5), as well as the job are listed in the third column.
  • Page 41: Printing Of A Measuring Report

    „Edit“. Press for the number keyboard. Press for the special signs keyboard. Press for the standard keyboard. 11.5 Printing of a measuring report Connect the ZRS 6060 with an external printer e.g. our optional portable USB-printer Page 41...
  • Page 42: Storing The Measuring Data On Usb Flash Drive

    Press to print out the current test report. The default settings about which information will be included in the test report can be changed in the menu as described in chapter 13.6.8 “Printer” on page 53. 11.6 Storing the measuring data on USB flash drive Connect a USB-flash drive to the USB-interface (host).
  • Page 43: Data Export And Mappingtools Software

    Client USB-interface (type B mini) for connection to a computer. 12.2 PC Mode Connect the ZRS 6060 with a USB-cable to a computer. On the touchscreen of the ZRS 6060 the message „PC Mode” will be displayed. After the instrument has been recognized, it will appear as a drive in Windows Explorer, similar to the picture on the left.
  • Page 44: Data Export To Microsoft

    The mapping browser can be deactivated as described in the separate instruction manual MappingTools. If the ZRS 6060 is equipped with the optional WAAS GPS-module and there was a valid signal during the measurements, then they will be displayed in the mapping browser.
  • Page 45 Page 45...
  • Page 46: Menu

    13 Menu 13.1 Menu structure Page 46...
  • Page 47: Navigation In The Menu

    13.2 Navigation in the menu Press to get to the menu where several settings can be set. On the top of each window you can read in which menu you are. Navigate in the menu as described in chapter 6 “Navigation”...
  • Page 48: Pass/Fail

    and select „Measure mode“ to Press activate average readings. A faster way is to press the symbol in the main window. If the symbol is shown, the average reading is activated. 13.3.3 Pass/Fail and select „Measure mode“ to Press activate the pass/fail function. Minimum reference value for a specimen of retroreflective material (e.g.
  • Page 49: Jobs

    If the interval timer is activated, the current setting for the interval time and interval counts can be seen. To change these settings, press on the respective row. The interval time can be set between 5 and 1000 seconds. The interval counts can be set between 2 and 500. 13.5 Jobs and select „Jobs“...
  • Page 50: Language

    Press required language. If a wrong language was selected and you are not able to get back to the language setup, switch off the ZRS 6060 by pressing the on/off button long. Press the measuring button continuously during switching on to get directly to the language settings.
  • Page 51: Date And Time

    13.6.3 Date and time select „Setup“ to set date and time. Press 13.6.4 Power and select „Setup“ to change „auto Press off time“. At low battery status, the indicated time is reduced automatically A time period between 2 and 120 minutes can be chosen.
  • Page 52: Camera

    and select „Setup“ to open the menu Press item „Database“. Here you can create a new database, open, rename or delete an existing database and export a database. Tip on the required row. Sometimes it is helpful to store all measurements for a specific project in a new database.
  • Page 53: Printer

    13.6.8 Printer and select „Setup“ to open the menu Press item „Printer“. In this menu you can set which information will be included in the test report printed by a USB printer. Top list Middle list Bottom list 13.6.9 Calibration After expiry of the selected calibration interval, the ZRS 6060 will remind you that a calibration is due.
  • Page 54: Display

    and select „Setup“ to select the units Press for temperature and length. You can choose between Celsius (°C) and Fahrenheit (°F), and between meters and miles respectively. 13.6.11 Display and select „Setup“ to open this Press menu item. Zehntner calibrates the touchscreen. However, in the course of time the precision of the touchscreen may abate.
  • Page 55: Diagnostics

    and select „Setup“ to reset the Press equipment to factory settings. The reset to factory default cannot be undone. If you are sure to carry out the reset to the factory default you need to confirm the message with „Yes”. 13.7 Diagnostics and select „Setup“...
  • Page 56: Built-In Battery And Charging

    In order to prevent damage to the battery, the instrument switches off automatically before the battery is completely drained. The ZRS 6060 announces this by displaying the symbol and a message.
  • Page 57: Status And Error Messages

    The battery may only be replaced by Proceq or by an authorized Proceq agent. If the unit hasn´t been used for a longer period of time, e.g. several months, it should be charged before using.
  • Page 58: Error Message "Calibration Is Not Ok

    Contact either Proceq or your authorized Proceq agent. 15.5 Error message “Factory calibration has expired” Page 58...
  • Page 59: Reset Of Zrs 6060

    Contact Proceq or your authorized Proceq agent for returning the unit. 15.6 Reset of ZRS 6060 If the firmware of the ZRS 6060 freezes, reset the instrument by shutting it off completely by pressing the on/off button long.
  • Page 60: Cleaning

    Please store the instrument including its accessories in the shoulder bag. Make sure that the ZRS 6060 is turned off and unplugged from the battery charger before maintenance. During cleaning take care that under no circumstances cleaning liquid flows into the interior of the instrument.
  • Page 61 16.3 Adjustment of display inclination resistance he force needed to tilt the display can be adjusted. We recommend using a plastic tool for fixing the screw in order to avoid scratches. Another possibility would be to use a coin e.g. the EUR 1.00 or 2.00 coin.
  • Page 62 Ø 25 mm (0.98“) Measuring area: Measuring sensor: adapted to V () 0 - 2‘000 cd⋅lx ⋅m Measuring range: Measuring period: approx. 3 seconds 1 GB SD flash memory, about 1‘000‘000 measurements Memory: without pictures or about 1‘000 up to 10‘000 with pictures, depending on picture resolution Interface: Host USB (type A), Client Mini USB (type B)
  • Page 63 Glossary Accumulator Calibration ....... 19, 54 Capacity ....... 52, 57 Calibration standard ....20 Changing ........58 Factory calibration ...... 60 Charging ........58 Last calibration ......56 Charging cycle ......57 On second calibration standard . 22 Status indication ......57 Calibration standard .......
  • Page 64 Barcode ........39 Information Error message ....... 58 Input .......... 42 Battery voltage ......58 Instrument Calibrate 0.2° ......58 Delivery ........10 Calibrate 0.33° ......59 Description ........8 Calibrate 0.5° ......59 Overview ........14 Calibrate 1.5° ......59 Transport ........
  • Page 65 Battery voltage ......58 Description ......... 31 Calibrate 0.2° ......58 Handles ........31 Calibrate 0.33° ......59 Illumination adapters....31 Calibrate 0.5° ......59 with modification of the ZRS 6060 Calibrate 1.5° ......59 ..........12 Calibrate 1° ........ 59 Page 65...
  • Page 66 Calibrate 2° ........ 59 Touchscreen ......... 16 Calibrate observation angle ..58 Inclination ........62 Calibration is not OK ....59 Inclination adjustment ....15 Factory calibration has expired .. 60 Navigation ......... 18 Storage ........12, 63 Scrolling ........18 Store Transport ........
  • Page 68 Subject to change. Copyright © 2017 by Proceq SA, Schwerzenbach. All rights reserved. www.proceq.com Version 2.1 dated 08.08.2017...