Proceq ZDR 6020 Instruction Manual page 43

Dynamic retroreflectometer rl
Table of Contents

Advertisement

Edit Filter Settings:
PassFailFilterSettings
Upper and lower limit for valid R
Presetting, see chapter 5.8.1 on page 37. Values outside of limits are discarded.
• PassFail:
• Pass Fail min:
• Pass Fail max:
Marking width filter
Maximum and minimum width of a valid marking. Taken from the current
Marking Presetting, see chapter 5.8.1 on page 37. Instead of millimetres, the
width given here is in bars. A bar represents one channel of the sensor, its width
in the measuring field is approx. 1.5 cm (100 cm / 64 = 1.5 cm). Values outside
of limits are discarded.
• Marking width filter:
• Min width in bars:
• Max width in bars:
MarkingGapsFilter
Number of gaps (in bars) allowed within and between markings.
• GapsFilter:
• Allowed Gaps within:
• Max Gaps between:
ToleranceBandFilterMarkingDetection
Max difference (tolerance band) of R
marking when measuring double or triple lines
• ToleranceBandFromTopIn%:
ToleranceBandFilterSingleMarking
Max difference (tolerance band) of R
channel when measuring single lines
• ToleranceBandFilter:
• ToleranceBandFromTopIn%:
RoadStudFilter
Road stud detection
InterruptedMarkingMask
Interrupted marking filter
Enable editing filter settings
values. Taken from the current Marking
L
Enable / disable filter
Lower limit, R
not valid if lower, default = 40
L
Upper limit, R
not valid if higher, default = 1000
L
Enable / disable filter
Lower limit, marking not valid if lower
Upper limit, marking not valid if higher
Enable / disable filter
Number of gaps allowed within a marking
Number of gaps allowed between two markings
value in % between best and worst
L
Tolerance band in %, default = 50
value in % between best and worst
L
Enable/disable filter
Tolerance band in %, default = 25