Electrical Data; Mechanical Data; Environmental Data - Leuze electronic ODS 10 Operating Instructions Manual

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

12.4

Electrical data

Tab. 12.7:
Electrical equipment
Operating voltage U
Supply voltage
Residual ripple
Open-circuit current
Switching output
Signal voltage high/low
Analog output
ODS10L1.8/LA...
IO-Link
12.5

Mechanical data

Tab. 12.8:
Mechanical data
Housing
Optics cover
Weight
Connection type
12.6

Environmental data

Tab. 12.9:
Environmental data
Ambient temperature (operation)
Ambient temperature (storage)
Protective circuit
VDE safety class
Degree of protection
Standards applied
Leuze electronic
18 V ... 30 V DC
B
incl. residual ripple
≤ 15 % of U
≤ 150 mA
Push-pull switching output
NOTICE!
The push-pull switching outputs must not be connected in parallel.
≥ (U
B
• Voltage
1 V ... 10 V / 0 V ... 10 V
R
• Current (factory setting)
4 V ... 20 mA, R
COM2 (38.4 baud), Vers. 1.1
min. cycle time: 2.3 ms
SIO is supported
Plastic
Glass
Connection type
• M12 connector: 70 g
• Connection cable, 2000 mm: 133 g
• Connection cable, 200 mm, with M12 connector: 90 g
M12 connector, turnable 90°
Connection cable, 2000 mm, wire cross section 5 x 0.14 mm
(5 x 26 AWG)
Connection cable, 200 mm, with M12 connector
-40 °C ... +50 °C
-40 °C ... +70 °C
Transient protection
Polarity reversal protection
Short circuit protection for all outputs
III
IP67
IEC 60947-5-2
B
- 2 V) / ≤ 2 V
≥ 2 kΩ
L
≤ 500 Ω
L
ODS 10
Technical data
2
62