Analog Output Menu - Leuze electronic ODS 10 Operating Instructions Manual

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

Level 1
Output Q2
3.4.4

Analog Output menu

The characteristic output curve of the analog output is set to pin 2 in the Analog Output menu.
NOTICE
The Analog Output menu is only available for sensors with analog output.
Level 1
Analog out-
put
Spreading the characteristic output curve
You can spread the characteristic output curve of the analog output according to your requirements.
Ä Select the current or voltage range of the analog output.
Ä Set the distance measurement value that corresponds to the lower limit of the measurement range
(4 mA, 1 V, 0 V).
Ä Set the distance measurement value that corresponds to the upper limit of the measurement range
(20 mA, 10 V).
It is also possible to invert the working range of the analog output, i.e., the lower limit of the measurement
range is set to a larger value than the upper limit. This creates a descending characteristic output curve.
Leuze electronic
Level 2
Level 3
Q2 Upper Sw. Pt.
Q2 Lower Sw. Pt.
Notice: For the limit values of the measurement range for your sensor, see chapter 12
"Technical data".
Q2 Hysteresis
Q2 Light/Dark
Level 2
Level 3
Position Max. Val.
Position Min. Val.
Notice: For the limit values of the measurement range for your sensor, see chapter 12
"Technical data".
Analog range
4 ... 20 mA
1 ... 10 V
0 ... 10 V
Description
Upper switching point
Lower switching point
Hysteresis
Behavior of the switching output if an
object is within the taught/configured
switching distance.
• Light switching; switching output
active (high)
• Dark switching; switching output
not active (low)
Description
Distance measurement value for
maximum voltage / maximum
current
Distance measurement value for
minimum voltage / minimum cur-
rent
Current/voltage range of the
analog output
ODS 10
Device description
Default
ODS10L1.8...:
4000 mm
ODS10L1-25.8...:
12500 mm
50 mm
ODS10L1.8...:
10 mm
ODS10L1-25.8...:
30 mm
Light
Default
Upper limit of the
measurement range
50 mm
X
17