Leuze electronic ODS 10 Operating Instructions Manual page 13

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

Navigating within the menus
Use the navigation button 
Activate the desired selection with the enter button 
The number of bars at the left edge of the display indicates the current menu level.
Selecting options
Set the desired option with the navigation button 
Resetting to factory settings
Ä While switching on the supply voltage, press the enter button 
factory settings.
Ä Press the enter button 
previously are permanently lost.
Press the navigation button 
NOTICE
You can also use the menu (see chapter 3.4 "Configuration / menu structure") or the Sen-
sor Studio configuration software to reset to factory settings (see chapter 8 "Connecting to a PC
– Sensor Studio").
3.3.3
Display
The display changes depending on the current operating mode. The following display modes exist:
• Menu display
Press one of the two control buttons once or twice to access the menu display.
For information on operating via the menu, see chapter 3.4 "Configuration / menu structure" and see
chapter 3.5 "Configuration example".
• Process mode
After switching on the supply voltage and error-free initialization of the device, the green LED lights up
continuously. The laser distance sensor is in process mode.
In process mode, the current measurement value is displayed in the display, e.g. "267 mm".
NOTICE
In the menu display, the selectable or editable values are shown with inverted text colors (black
on white background).
If no key is pressed for approx. 6 minutes in the configuration menu, the device automatically re-
turns to the process mode.
The sensor can be protected against unauthorized configuration change by activating the pass-
word query (see chapter 3.4.6 "Settings menu"). The password is permanently set to 165. In ad-
dition, a complete button lock can be activated using the lock function (device access locks,
bit 2) (see the table "Status displays on the display").
Leuze electronic
 to move through the menu.
 and the enter button 
again to reset all parameters to factory settings. All parameter settings made
to return to process mode without resetting the parameters.
ODS 10
.
.
to reset the sensor configuration to the
Device description