3.4.1
Input menu
The function of the switching input on pin 5 is set in the Input menu.
NOTICE
The Input menu is only available for sensors with switching input.
Level 1
Input
Important: Activation or deactivation using IO-Link commands only has an effect if neither Deactivation
nor Activation is set as the input function.
3.4.2
Output Q1 menu
The switching behavior of switching output Q1 on pin 4 is set in the Output Q1 menu.
Level 1
Output Q1
3.4.3
Output Q2 menu
• ODS10LA6: The switching behavior of switching output Q2 is set to pin 5 in the Output Q2 menu.
• ODS10L6X: The switching behavior of switching output Q2 is set to pin 2 in the Output Q2 menu.
NOTICE
The Output Q2 menu is only available for sensors with a second switching output Q2.
Leuze electronic
Level 2
Level 3
Input Mode
No Function
Teach
Deactivation
Activation
Level 2
Level 3
Q1 Upper Sw. Pt.
Q1 Lower Sw. Pt.
Notice: For the limit values of the measurement range for your sensor, see chapter 12
"Technical data".
Q1 Hysteresis
Q1 Light/Dark
Description
Function of the switching input on pin 5 if the supply voltage
is applied.
No input function active
Teach analog output and switching out-
put
Switch off laser transmitter with +24 V
on the switching input
Switch on laser transmitter with +24 V
on the switching input
Description
Upper switching point
Lower switching point
Hysteresis
Behavior of the switching output if an
object is within the taught/configured
switching distance.
• Light switching; switching output
active (high)
• Dark switching; switching output
not active (low)
ODS 10
Device description
Default
X
Default
ODS10L1.8...:
4000 mm
ODS10L1-25.8...:
12500 mm
50 mm
ODS10L1.8...:
10 mm
ODS10L1-25.8...:
30 mm
Light
16