I [mA]
U [V]
ca. 24
ca. 11
20
10
4
1
ca 2.5
0
A
Area not defined
B
Linearity not defined
C
Measurement range
D
Object present
E
No object detected
F
Measurement distance
Fig. 7.2:
Behavior of analog output ODS10L1.8/L (factory setting)
7.1.2

Teaching the analog output

You can set the characteristic output curve for the analog output as follows:
• via the configuration menu
• via IO-Link
• via the Sensor Studio configuration software (see chapter 8 "Connecting to a PC – Sensor Studio")
Alternatively, you can teach the analog output using IO-Link commands or via the switching input (pin 5).
NOTICE
The teach-in described below is only possible for sensors with switching input.
Ä Activate teaching in the configuration menu via the OLED display and keyboard:
Input > Input Mode > Teach
NOTICE
Move through the configuration menu with the navigation button 
Activate the desired selection with the enter button 
Ä Position the measurement object at the desired distance.
Leuze electronic
0
30
50
8000 8500
.
ODS 10
Starting up the device
[
ca. 8500
.
]