Indicators In The Display - Leuze electronic ODS 10 Operating Instructions Manual

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

9.3

Indicators in the display

You can use the status indicators in the display to ascertain general error causes; (see chapter 3.3.3 "Dis-
play").
Tab. 9.3:
Display indicators – causes and measures
Display
Leuze electronic
Possible cause
Warning message, e.g., weak
reception signal
No object detected or recep-
tion signal too weak
Signal failure
Sensor defective
The current measurement
value is less than the lower
limit of the analog output dis-
tance
The current measurement
value is greater than the upper
limit of the analog output dis-
tance
ODS 10
Measures
Optimize object alignment
Position object in the measurement range
If the icon is displayed continuously: contact
Leuze electronic customer service (see chapter
11 "Service and support")
Change the setting for the lower limit of the
measurement range (see chapter 3.4.4 "Analog
Output menu")
Change the setting for the upper limit of the
measurement range (see chapter 3.4.4 "Analog
Output menu")
Troubleshooting
55