Ä Activate the teach input (pin 5) by applying a signal (see figure below).
The width of the low level at the teach input is determined by the teach-in function.
Tab. 7.1:
Teach-in function depending on the duration of the teach signal
Teach-in function
Distance value for the start of the measurement range
Corresponds to 1 V or 4 mA on the analog output (pin 5)
Distance value for the end of the measurement range
Corresponds to 10 V or 20 mA on the analog output (pin 5)
+24V
0V
T
Duration of the teach signal
Fig. 7.3:
Plot of the teach signal
Ä Ensure that the teach values are taken over correctly by checking the corresponding entries in the con-
figuration menu.
7.2

Setting the switching outputs

NOTICE
All sensors have a switching output Q1. Sensor models with an additional "6" in the part number
code have a second switching output Q2.
7.2.1

Configuring switching outputs

For each switching output you can configure the following parameters:
• Upper and lower switching point
• Hysteresis
• Switching behavior
Light switching or dark switching
Leuze electronic
T
ODS 10
Starting up the device
Duration of the teach signal (T)
120 ms ... 180 ms
220 ms ... 280 ms
t
35