Configuration Example - Leuze electronic ODS 10 Operating Instructions Manual

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

Central storage of configuration data
If the configuration setting is ended with subsequent adoption of the data in the data memory of a con-
nected IO-Link master, the sensor does not need to be newly configured if a device is changed.
The sensor adopts the configuration from the data memory of the connected IO-Link master, provided that
the IO-Link master is capable of doing this and enabled accordingly.
Timeout
If configuration setting is ended due to timeout, the previously made changes are saved locally in a non-
volatile memory. The status of the DSUpload flag is not changed.
If the DSUpload flag is not set, after reconnection the change is overwritten by the configuration which is
stored in the data memory of the connected IO-Link master.
NOTICE
If the sensor is not operated via an IO-Link master, it is recommended to end the configuration
setting using Menu Exit or Exit DSUpld=0.
3.5

Configuration example

To illustrate menu operation, the setting of the lower switching point of switching output Q1 to 100 mm is
explained as an example.
Ä In process mode, press a control button to activate the menu display.
Input
Output Q1
Ä Press the navigation button 
ð The display shows "Output Q1" in the upper menu line.
Output Q1
Output
Ä Press the enter button 
Q1 Upper Sw. Pt.
08000 mm
Ä Press the navigation button 
ð The display shows "Q1 Lower Sw. Pt." in the upper menu line.
Q1 Lower Sw. Pt.
00050 mm
Ä Press the enter button 
ð The first digit of the switching point value is displayed with inverted colors.
Q1 Lower Sw. Pt.
00050 mm
Leuze electronic
.
to select Output Q1.
once.
to set the lower switching point.
ODS 10
Device description
22