3.2
Connection technology
For the electrical connection of the laser distance sensor, the following connection variants are available:
• M12 connector, 5-pin
• Connection cable, 2000 mm, 5-wire
• Connection cable, 200 mm, with M12 connector, 5-pin
3.3
Indicators and operational controls
The device housing is provided with the following indicators and operational controls:
• OLED display
• Two control buttons
• Green/red LED on the control panel
• Two yellow LEDs:
• On the control panel
• On the lens cover
1
3
1
Green/red LED (PWR)
2
Yellow LED (Q1/Q2)
3
Display
4
Control buttons
Fig. 3.2:
Indicators and operational controls
3.3.1
LED indicators
Tab. 3.1:
Meaning of the LED indicators on the device housing
LED
Green/red LED
PWR
Yellow LED
Switching output Q1/Q2
3.3.2
Control buttons
The sensor is configured via the display and control buttons. The display is controlled via the control but-
tons. You can make adjustments in the application via the control buttons.
•
– Scroll through the functions
•
– Enter button: select function, confirm/enter value
The
and
buttons have different functions depending on the operating situation. These functions are
displayed via icons at the right edge of the display (see chapter 3.3.4 "Meaning of the display icons").
Leuze electronic
2
4
Color, state
Green
Orange
Red
Off
On
Off
ODS 10
Description
Sensor ready
Warning, weak signal
No signal
No supply voltage
Object detected in the switching range
No object detected in the switching range
Device description
12