Kipp & Zonen BREWER MK IV Instruction Manual page 123

Table of Contents

Advertisement

PMT.WINDOW.TIME
RESET.TIME.OUT
RH.ORIGIN
RH.SLOPE
SUPPLY.CONVERSION
[<powerSupply>]
SUPPLY.DELTA
[<powerSupply>]
SUPPLY.NOMINAL
[powerSupply>]
TEMP.DELTA [thermalPoint>] float
TEMP.NOMINAL
[<thermalPoint>]
TEMP.ORIGIN
[<thermalPoint>]
TEMP.SLOPE [<thermalPoint>] Float degrees/volt
TRACKER.DEBOUNCE.TIME Float seconds
USE.B3.FOR.LAMPS
VERSION.ELEC
VOLTS.PER.BIT
Possible <index>es
<index>
<address>
<analogPt>
<digitalPt>
<lamp>
<motorId>
<powerSupply>
<thermalPoint>
<trackerSwitch>
Examples
?MOTOR.MAX.ACC[IRIS]
reports the current maximum acceleration for the iris motor.
!PMT.HV.TOLERANCE 50
sets the value of the high voltage tolerance to 50 millivolts.
1
The first character must be a digit. The number interpreted as decimal unless the first digit is a 0 in which
case the second character is tested. If it is 'x' or 'X' the remaining digits are interpreted as a hexadecimal
number. If the second character is a digit the number is interpreted as octal.
120
float seconds
unsigned integer
seconds
float
volt at 0 RH
Float
volt/%
float
float
volts
float
volts
degrees
float
degrees
float
degrees
Boolean
unsigned byte
Float
volts
Meaning
location within the space
which A/D mux input
which digital input
which Brewer internal lamp
identifies a motor
identifies a power supply
identifies a thermal sensor
identifies a tracker switch
digital input
MKIV OPERATOR'S MANUAL
seconds in a window. Should be an integral
Immediate
multiple of PMT resolution time.
the length of time allowed for initialization of all
on reset
motors. This should be larger than the largest
value of MOTOR.TIME.OUT.
Humidity sensor calibration provided by
immediate
manufacturer
Humidity sensor calibration provided by
immediate
manufacturer
Number of volts at the output of the supply to
Immediate
read one volt via the A/D
Permitted (max-nominal and nominal-min)
on reset
voltage in watermark recording
on reset
Center voltage in watermark recording
Permitted (max-nominal and nominal-min)
on reset
temperature excursion in watermark recording
on reset
Center temperature in watermark recording
number of degrees Celsius offset for 0 volts at
Immediate
the A/D
number of degrees Celsius per volt at the A/D
immediate
(linear thermistors are used here)
immediate
debounce time for the tracker control switches
Sets response to command: B,3. If set to YES,
immediate
lamps are turned on else the command is
ignored.
immediate
Records the electronics version
Resolution of A/D converter in volts per A/D unit
immediate
(bit)
possibilities/format
ANSI C integer format
integer 0 to 23
integer 0 to 15
0 to 1 or identifier - One of: HG, STD
see section on I command
0 to 6 or identifier
HV, +12V, +5V, -12V, +24V, +5VSEC
(secondary supply), -5VSEC
0 to 5 or identifier
PMT (photomultiplier), FAN (internal temperature),
BASE, BELOW.SPECTRO,
WINDOW.AREA, EXTERNAL (external temperature)
0 to 4 or identifier
CW, CCW, UP, DOWN, COARSE
1
One of:
One of:
One of: