User Manual - DPM2 Series Process Panel Meters
Technical Specifications
Process Input
Sensor Excitation
Potentiometer
Resistance
Fixed Display Range
/ Resolution
Measurement current
Maximum resistance
per wire
Linearization
Coefficient
Accuracy
Temperature
Thermocouple
Fixed Display Range
/ Resolution
Cold junction
compensation range
Accuracy
26
Technical Specifications
Range
Input Impedance
±20mA
<20Ω
±10V
2MΩ
±200V
2MΩ
Maximum
Range
Measurement
Current
100-100kΩ
<0.4mA
999.9Ω
2.3mA
9999Ω
230µA
50kΩ
23µA
RTD
Pt100 (3 wire)
J
-150.0°C to
999.9°C / 0.1°C
-150°C to
1100°C / 1°C
-238.0°F to
999.9°F / 0.1°F
-238°F to
2012°F / 1°F
±(0.1% rdg+0.6°C)
±(0.1% rdg+1.1°F)
DPM2 Process User Manual, 1st Edition
Resolution
2µA
1mV
20mV
24V±3V @ 30mA
Resolution
0.01% F.S.
0.1Ω
1Ω
10Ω
-200.0°C to 800.0°C / 0.1°C
-200°C to 800°C / 1°C
-328.0°F to 999.9°F / 0.1°F
-328°F to 1472°F / 1°F
1mA
40Ω (balanced)
IEC 60751
0.00385
±(0.15% rdg+0.5°C), t<-50°C ±(1% rdg+0.5°C)
±(0.15% rdg+0.9°F), t<-58°F ±(1% rdg+0.9°F)
K
-150.0°C to
999.9°C / 0.1°C
-150°C to
1200°C / 1°C
-238.0°F to
999.9°F / 0.1°F
-238°F to
2192°F / 1°F
-10°C to 60°C (14°F to 140°F)
Accuracy
±(0.1% rdg+15µA)
±(0.1% rdg+6mV)
±(0.1% rdg+0.1V)
Accuracy
±(0.1% rdg+0.05% F.S.)
±(0.1% rdg+0.7Ω)
±(0.1% rdg+6Ω)
±(0.1% rdg+35Ω)
Pt1000 (2 wire)
100µA
-
T
-150.0°C to
-150.0°C to
400.0°C / 0.1°C
999.9°C / 0.1°C
-150°C to
400°C / 1°C
1300°C / 1°C
-238.0°F to
-238.0°F to
752.0°F / 0.1°F
999.9°F / 0.1°F
-238°F to
752°F / 1°F
2372°F / 1°F
±(0.2% rdg+0.8°C)
±(0.1% rdg+0.6°C)
±(0.2% rdg+1.5°F)
±(0.1% rdg+1.1°F)
N
-150°C to
-238°F to