OPERATING CONTROLS AND PROCEDURES
REMOTE TRAFFIC where bank one is transmitter
identification and bank two property code of hand-held
radio remote. The two banks work together and
continuously display information for each radio remote in
immediate area.
NOTE:
Cranes with 2.4 Ghz wireless systems will not
display traffic information.

Block Level Sensor

*BLOCK LEVEL SENSOR

BLOCK ANGLE
DRUM 1 PUMP
DRUM 2 PUMP
The LEVEL screen displays the following information:
BLOCK LEVEL SENSOR - where the block identification
code is entered and displayed. To enter a block identification
code, press select. The cursor (*) appears next to Block
Level Sensor. Press select again to enter identification code
area. Scroll up or down to enter 0 to 9, press select to move
through each four positions.
BLOCK ANGLE - where the block angle is displayed. A block
level fault occurs if the maximum block angle for parts of line
is exceeded:
Angle in Degree
10
8.8
7.6
6.4
5.2
4.0
3-64
+ 3.43 DEG
30 %
31 %
LEVEL
Parts of Line
16 or less
20
24
28
32
36
Published 12-05-17, Control # 032-23

Crane Mode

Crane Mode - STANDARD
PROG M0000000.ONP
The crane mode screen displays the selected crane mode:

Crane mode

PROG is computer program version
CON is computer and crane configuration code

Hydraulic Fan (Tier 4 only)

The hydraulic fan screen displays the following information
for the Tier 4 hydraulic fan system:
PRESS – Fan system pressure. Increased cooling
demand and increased engine speed will increase this
pressure.
PUMP – Displays the current pump command. This will
range from 5 to 100% and change in response to cooling
demand and engine speed.
STATUS – Displays the error status of the fan system:
0 = no fault
Bit 1 = fan pressure transducer out of range
Bit 2 = fan control valve digital output fault
Bit 3 = fault is set if fan pressure is below 500 psi (34,5
bar) after the system is initialized. Will cause the backup
coil to energize and try to fully stroke the pump.
18000 OPERATOR MANUAL
CON 000000
PRESS
000 PSI
PUMP
0 %
STATUS
0
HYRAULIC FAN