Changing the detectors settings could result
in a configuration that has not been 3rd party
performance approved.
IMPORTANT!
For flame detectors with LON output, the EQP
controller will override any settings made with
the Enhanced Flame Inspector software, with the
exception of the Hangar Mode on the X3301.

DESCRIPTION

Det-Tronics X-Series Flame Detectors record pertinent
configuration and event information in the device's non-
volatile memory. Important detector status data such
as power-up/down, faults and alarms are date and time
stamped as they occur and stored in the electronic
module located inside the detector enclosure. The
Inspector Monitor software allows the user to later upload
this data to a personal computer (PC) where it can be
displayed, saved and/or printed.
Enhanced Flame Inspector Software is compatible with
all versions of X3301, X3302, X9800, X5200 and X2200
flame detectors.

FEATURES

Data logging capability for Det-Tronics flame
detectors.
Data stored in non-volatile memory.
Data can be uploaded to a PC.
Data can be viewed, stored to a file, or printed.
©Detector Electronics Corporation 2019
3 .1
Last Manual Update: 12/18/19
NOTE
Enhanced Flame Inspector Software
for use with Det-Tronics
X-Series Flame Detectors

HARDWARE REQUIREMENTS

Enhanced Flame Inspector software is designed for
PCs using the Windows operating system.
A minimum of 16 megabytes of RAM are required;
however, 32 or more megabytes are recommended for
optimum performance. The software requires a color
monitor with a minimum resolution of 640 by 480.
A hard drive with at least 10 megabytes of free space
is also required. The system can utilize any properly
installed printer.

INSTALLATION

WIRING

Hardwired Method
It is recommended to connect the detector's RS-485
terminals (terminals 23 and 24) to the PC at the time of
installation. This will allow Inspector Monitor to function
at any time, without the need to open the detector
housing and remove the sensor module ("front" half of
the detector) prior to test. A RS-485 to USB converter
(p/n 103881-001) is required for proper communication.