X2200/X5200/X9800 EVENT LOG DESCRIPTIONS AND TROUBLESHOOTING
Event Description
Background IR Fault
Background UV Fault
CPU Fault
Data Log Reset
Input Voltage Out of Range
Internal Power Supply
Out of Range
Internal Processing Fault
IR Manual
Fault
o i
IR Module Fault
IR
Calibration Failed
o i
IR
Fault
o i
Manual
Test at Boot Fault
o i
RTC Fault
Temperature Out of Range
UV Manual
Fault
o i
UV
Calibration Failed
o i
UV
Fault
o i
UV Tube Fault
3.1
Status Condition
IR levels have caused IR detection range to
reduce by more than 50%.
UV levels have caused UV detection range
to reduce by more than 50%.
An internal processing error occurred.
All events in the log are cleared.
The input voltage is not within 18Vdc to
30Vdc.
Internal failure.
An internal processing error occurred.
IR detection has been reduced by more
than 50%.
Failure on the IR circuit.
IR Optical Integrity (
) calibration failed.
o i
Auto or Manual IR Optical Integrity (
The Manual
test line was reported to be
o i
active at power up
Real time clock communications fault.
The temperature reported is outside of the
recommended operating range.
UV detection has been reduced by more
than 50%.
UV Optical Integrity (
) calibration failed.
o i
Auto or Manual UV Optical Integrity (
Failure on the UV circuit.
Recommended Action
Check detector field of view for IR sources, re-aim if
needed. Check sensitivity setting.
Check detector field of view for UV sources, re-aim if
needed. Check sensitivity setting.
Return to the factory.
Performed at the factory only
Check the power supply and input power wiring.
Return to the factory.
Return to the factory.
Clean detector windows and
Re-initiate manual Optical Integrity (
if the detector does not return to normal status.
o i
Return to the factory.
Clean detector windows and
Re-initiate IR Optical Integrity calibration. Return to the
factory if the detector will not complete a calibration.
Clean the detector windows and
) fault
o i
Perform a IR Optical Integrity Calibration if necessary.
Check Manual Optical Integrity terminals and wiring for a
potential short or activation.
Set the RTC via the Flame Inspector Software. If the fault
is reoccurring return to the factory.
Relocate detector or provide a shield from the heat
source.
Clean detector windows and
Re-initiate manual Optical Integrity (o i ) test. Calibrate o i
if the detector does not return to normal status.
Clean detector windows and
Re-initiate UV Optical Integrity calibration. Return to the
factory if the detector will not complete a calibration.
Clean the detector windows and
) fault
o i
Perform a UV Optical Integrity Calibration if necessary.
Return to the factory.
16
reflector plate.
o i
) test. Calibrate IR
o i
reflector plate.
o i
reflector plate.
o i
reflector plate.
o i
reflector plate.
o i
reflector plate.
o i
95-8751