Sign In
Upload
Manuals
Brands
Det-Tronics Manuals
Security Sensors
X3301
Det-Tronics X3301 Manuals
Manuals and User Guides for Det-Tronics X3301. We have
7
Det-Tronics X3301 manuals available for free PDF download: Instructions Manual, Addendum
Det-Tronics X3301 Instructions Manual (43 pages)
Multispectrum IR Flame Detector
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 1.75 MB
Table of Contents
Table of Contents
2
Description
3
Outputs
3
Led
4
O I (Optical Integrity)
4
Communication
5
Data Logging
5
Integral Wiring Compartment
5
Detector Sensitivity Levels
5
General Application Information
6
Response Characteristics
6
Important Application Considerations
6
Important Safety NOTES
6
Installation
7
Detector Positioning
7
Detector Orientation
8
Protection against Moisture Damage
8
Wiring Procedure
8
Setting Device Network Addresses (EQP Model Only)
15
Startup PROCEDURE
16
Fire Alarm Test
16
Troubleshooting
16
Maintenance
17
Cleaning Procedure
17
O I Plate Removal and Replacement
17
Periodic Checkout Procedure
18
Clock Battery
18
Features
18
Specifications
19
Replacement Parts
21
Replacement Parts List
21
DEVICE Repair and RETURN
21
ORDERING Information
21
Accessories
21
X3301 Model Matrix
22
HIGH RESOLUTION FIELD of VIEW Diagrams
23
Appendix A - FM Approval and Performance REPORT
27
Appendix B Csa Approval
35
Appendix Catex Approval
36
Appendix Diecex Approval
38
Appendix Een54 Approvals
39
Appendix F - OFFSHORE Approvals
40
Appendix Gadditional Approvals
41
Appendix H - Declaration of Conformity
42
Advertisement
Det-Tronics X3301 Instructions Manual (39 pages)
Multispectrum IR Flame Detector with Pulse Output
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 2.39 MB
Table of Contents
Table of Contents
2
Description
3
Outputs
4
Led
4
O I (Optical Integrity)
4
Communication
5
Data Logging
5
Detector Sensitivity Levels
5
Integral Wiring Compartment
5
General Application Information
6
Response Characteristics
6
Important Application Considerations
6
Important Safety Notes
6
Installation
7
Detector Positioning
7
Detector Orientation
7
Protection against Moisture Damage
8
Wiring Procedure
8
Startup Procedure
16
Manual O I Test (Output to Controller)
16
Count Test Mode (Output to Controller)
16
Fire Alarm Test (Pulse Output to Fire Alarm Panel)
17
Troubleshooting
17
Maintenance
18
Cleaning Procedure
18
O I Plate Removal and Replacement
18
Clock Battery
19
Features
19
Periodic Checkout Procedure
19
Specifications
19
Device Repair and Return
21
Ordering Information
21
Accessories
21
X3301 Model Matrix
22
Appendix A - Fm Approval and
23
Replacement Parts
21
Performance Report
23
Appendix B - Csa Approval
33
Appendix C - Atex / Ce Approval
34
APPENDIX Diecex APPROVAL
36
Appendix Een54 Approvals
37
Appendix Fadditional Approvals
38
Det-Tronics X3301 Instructions Manual (27 pages)
Protect-IR Multispectrum IR Flame Detector with Pulse Output
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 0.29 MB
Table of Contents
Table of Contents
2
Description
3
Detector Status Indicator
4
General Application Information
5
Response Characteristics
5
Important Application Considerations
5
Important Safety Notes
5
Installation
6
Detector Positioning
6
Detector Orientation
6
List of Illustrations Detector Orientation Relative to Horizon
6
Front View of the X3301
6
Wire Size and Type
7
Protection against Moisture Damage
7
Wiring Procedure
7
Figure
8
EOL Resistors
8
Q9033B Mounting Bracket Dimensions in Inches (CM)
8
X3301 Terminal Block
8
X3301 Wiring Terminal Identification
8
Figure 6-A Typical System, X3301 Detectors Wired to R7404 Controller
9
Figure 7-A Typical System, X3301 Detectors Wired to R7404 Star Logic Controller
10
Figure 8-A Typical System, X3301 Detectors Wired to R7494 Controller
11
A Typical System, X3301 Detectors Wired to R7495 Controller
12
Figure 10 a Typical System, X3301 Detectors Wired to R7405 Controller
13
Figure 11A Eex D Wiring Option
14
Figure 11B Eex E Wiring Option
14
Startup Procedure
15
Manual O I Test
15
Count Test Mode
15
Fire Alarm Test
15
Figure 12 EOL Resistor Installation
15
Troubleshooting
16
Periodic Checkout Procedure
16
Maintenance
16
Cleaning Procedure
16
Oi PLATE REMOVAL
17
Clock Battery
17
Features
17
Specifications
17
Figure 13 Oi Plate Removal
17
Figure 14 X3301 Dimensions in Inches (CM)
18
Replacement Parts
19
Device Repair and Return
19
Ordering Information
19
Appendix A
20
Advertisement
Det-Tronics X3301 Instructions Manual (28 pages)
Multispectrum IR Flame Detector
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 0.34 MB
Table of Contents
Table of Contents
2
Description
3
Outputs
3
Led
4
Optical Integrity (Oi)
4
Communication
5
Data Logging
5
Integral Wiring Compartment
5
General Application Information
5
Response Characteristics
5
Important Application Considerations
5
Important Safety Notes
6
Installation
6
Detector Positioning
6
Detector Orientation
7
Protection against Moisture Damage
7
Wiring Procedure
7
Setting Device Network Addresses (EQP Model Only)
14
Startup Procedure
15
Fire Alarm Test
15
Troubleshooting
15
Maintenance
15
Cleaning Procedure
16
Oi Plate Removal
16
Periodic Checkout Procedure
16
Clock Battery
16
Features
17
Specifications
17
Replacement Parts
19
Device Repair and Return
19
Ordering Information
19
Accessories
19
Det-Tronics X3301 Addendum (21 pages)
HART Communication with the Multispectrum IR Flame Detector
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 1.27 MB
Table of Contents
Table of Contents
2
Interconnecting the HART Communicator with the Detector
3
HART Device Description Language
5
Detector Wiring
5
HART Menu Structure
6
X3301 Root Menu
7
Device Info Menu
7
General Info Menu
8
HART Info Menu
9
HART PV Menu
10
Condensed Status
11
Status Info Menu
12
Hardware Menu
13
O I Menu
14
Detector Settings
15
History Menu
15
Command Menu
16
HART CMD Menu
17
Device Setup Menu
17
Configuration Menu
18
Calibration Menu
18
Write Protect
19
HART Setup
19
Real Time Clock
20
Det-Tronics X3301 Instructions Manual (20 pages)
Enhanced Flame Inspector Software for use with Det-Tronics Flame Detectors
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 2.58 MB
Table of Contents
Table of Contents
2
Description
3
Features
3
Hardware Requirements
3
Installation
3
Wiring
3
Software
5
Startup
5
Determining Detector Configuration and Programming
10
Determining Current Status Conditions
10
Manual O I Initiated by Magnet / Switch
10
Test
10
Manual O I Test Initiated by Enhanced Flame Inspector
11
O I CALIBRATION
13
4-20 Ma TEST / CALIBRATION
13
Monitoring the Detector's Event Logs
14
Sort Order
14
Saving Files
14
Event Logs Descriptions
14
Troubleshooting
17
Replacement Parts
19
Ordering Information
19
Det-Tronics X3301 Addendum (16 pages)
Flame Detectors with Pulse Output
Brand:
Det-Tronics
| Category:
Security Sensors
| Size: 1.12 MB
Table of Contents
Table of Contents
2
Description
3
Outputs
4
O I (Optical Integrity)
4
General Application Information
5
Response Characteristics
5
Important Application Considerations
5
Important Safety Notes
5
Wiring Procedure
5
Wire Size and Type
5
Detector Wiring
6
Startup Procedure
12
Manual O I Test (Output to Controller)
12
Count Test Mode (Output to Controller)
12
Fire Alarm Test (Pulse Output to Fire Alarm Panel)
12
Maintenance
13
Periodic Checkout Procedure
13
Certification
13
Model Matrix
14
Advertisement
Related Products
Det-Tronics X5200
Det-Tronics X2200M
Det-Tronics X2200G
Det-Tronics X3302
Det-Tronics X5202
Det-Tronics X Series
DET-TRONICS X3300
DET-TRONICS X9800
Det-Tronics x2200
Det-Tronics X5200G
Det-Tronics Categories
Security Sensors
Gas Detectors
Measuring Instruments
Control Unit
Controller
More Det-Tronics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk