Beretta EXCLUSIVE C Series Installer And User Manual page 38

Hide thumbs Also See for EXCLUSIVE C Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
EXCLUSIVE
PARAMETERS
Number of fan rotations with slow ignition
Maximum number of heating fan rotations
Maximum number of DHW fan rotations
Minimum number of heating fan rotations
Minimum number of DHW fan rotations
Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater
inlet).
NOTE (if the outdoor temperature sensor or the control panel, or even both devices, are present in the boiler)
With reference to the Delegated Regulation (EU) No. 811/2013, the information in the table can be used for completing the product data sheet and the labelling
for room heating appliances, for mixed heating appliances, for all those appliances for enclosed space heating, for temperature control devices and solar devices:
ADDED DEVICES
OUTDOOR TEMPERATURE SENSOR
CONTROL PANEL (*)
OUTDOOR TEMPERATURE SENSOR + CONTROL PANEL (*)
(*) Set as ambient regulator
Via Risorgimento 13 - 23900 Lecco (LC) Italy
Exclusive C
D: l/min
Serial N.
NOx:
230 V ~ 50 Hz
W
IP
Pmw =
bar T=
°C
Pms =
bar T=
°C
38
Qn
Qn
Qm
80-60 °C
80-60 °C
Qn (Hi) =
kW
kW
kW
Pn =
kW
kW
kW
UM
METHANE GAS (G20)
rpm
rpm
rpm
rpm
rpm
Symbol
EXCLUSIVE
25C
-
A
-
A
Pnominal
18
ηs
94
P4
17,6
P1
5,9
η4
88,2
η1
98,9
elmax
28,0
elmin
14,0
PSB
3,0
Pstby
42,0
Pign
-
QHE
37
LWA
51
NOx
46
XL
ηwh
86
Qelec
0,127
Qfuel
22,777
AEC
28
AFC
17
CLASS
II
V
VI
Serial number plate
Domestic hot water function
Heating function
Qn
Nominal heat delivery
Pn
Nominal heat output
Qmin
Qn
Qm
Reduced heat delivery
80-60 °C
50-30 °C
Qmin
Minimal heat output
kW
IP
Degree of Protection
Pmw
Maximum DHW pressure
kW
kW
Pms
Maximum heating pressure
T
Temperature
D
Specific flow rate
NOx
NOx class
EXCLUSIVE
5.000
7.000
8.400
1.600
1.600
EXCLUSIVE
EXCLUSIVE
30C
35C
A
A
A
A
24
31
94
94
23,5
31,4
7,9
10,5
88,3
88,2
98,9
98,6
37,0
31,4
14,0
10,5
3,0
3,0
42,0
46,0
-
-
42
56
53
54
33
48
XL
XL
85
85
0,167
0,167
22,921
22,993
37
37
17
17
LPG (G31)
5.000
7.000
8.300
2.000
2.000
EXCLUSIVE
Unit
42C
A
-
A
-
34
kW
94
%
34,3
kW
11,5
kW
88,2
%
98,5
%
34,3
W
11,5
W
3,0
W
42,0
W
-
W
62
GJ
51
dB
44
mg/kWh
XL
84
%
0,142
kWh
23,278
kWh
31
kWh
18
GJ
BONUS
2%
3%
4%

Advertisement

Table of Contents
loading

Table of Contents