It is possible to return to the start page at any time by keeping the key
"back" pressed for at least 2 seconds.
Note: once enabled, the ERROR HISTORY function can no longer be
disabled; there is no procedure for resetting the error history.
If an alarm repeats consecutively, it is saved only once.
5.17 Temporary switch-off
In the event of temporary absences (weekends, short breaks, etc.) set the
status of the boiler to OFF
.
HOT WATER ONLY
HEATING AND HOT WATER
While the electrical supply and the fuel supply remain active, the boiler is
protected by the systems:
- heating anti-freeze: this function is activated if the temperature
measured by the flow sensor drops below 5°C. A heat request is
generated in this phase with the ignition of the burner at minimum output,
which is maintained until the outlet water temperature reaches 35° C;
- domestic hot water anti-freeze: the function starts if the temperature
measured by the DHW NTC probe falls below 5°C. A heat request is
generated in this phase with the ignition of the burner at minimum output,
which is maintained until the outlet water temperature reaches 55° C.
b
The activation of the ANTI FREEZE function is indicated by a scrolling
message on the foot of the REC10 display.
- circulator anti-locking: the circulator activates every 24 hours of
stoppage for 30 seconds.
5.18 Switching off for lengthy periods
If the EXCLUSIVE boiler is not used for a long time, the following operations
must be carried out:
- set the status of the boiler to OFF
- set the system's main switch to "off"
- close the fuel and water taps of the heating and domestic hot water
system.
In this case, the anti-freeze and anti-blocking systems are deactivated.
Drain the heating and domestic water system if there is any risk of freezing.
HOT WATER ONLY
HEATING AND HOT WATER
Closing
position
5.19 System reset
b
This operation must be carried out only by professionally qualified
personnel.
Whenever necessary, it is possible to restore the factory settings by
carrying out a SYSTEM RESET:
BOILER
BOILER
OFF
OFF
SUMMER
WINTER
BOILER
BOILER
OFF
OFF
SUMMER
WINTER
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select INSTALLATION with the "up" and "down" keys, confirming the
selection
INSTALLATION
WEATHER COMPENSATION
THERMOREGULATION
RANGE RATED
CALIBRATION
INSTALLER
INSTALLER
- select SYSTEM RESET with the "up" and "down" keys, confirming the
selection
INSTALLATION
ZONES MANAGER
ZONES MANAGER
SENSOR CALIBRATION
SENSOR CALIBRATION
SYSTEM RESET
INSTALLER
INSTALLER
- select CONFIRM to conform the system reset or else CANCEL to cancel
the operation.
Note: after a reset it is necessary to carry out a new configuration of the
system; for details about this procedure, see the following section.
5.20 System configuration
b
This operation must be carried out only by professionally qualified
personnel.
When restarting after a replacement of the REC10 rather than after
a SYSTEM RESET, the remote control displays an initial screen with
the firmware revision. Pressing "ok" a guided procedure is started for
configuring the system; select the desired options with the "up" and
"down" keys, confirming the selections made:
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY TO
PRESS ANY KEY
TO CONTINUE
- LANGUAGE selection:
ENGLISH
TECHNICAL
TECHNICAL
INSTALLATION
PARAMETERS
PARAMETERS
RANGE RATED
CALIBRATION
SYSTEM RESET
CONFIRM
CONFIRM
CANCEL
CANCEL
CONTINUE
ENGLISH
25