Beretta EXCLUSIVE X Installer And User Manual

Beretta EXCLUSIVE X Installer And User Manual

Hide thumbs Also See for EXCLUSIVE X:

Advertisement

Quick Links

Installer and user manual
EXCLUSIVE X
EN
INSTALLER AND USER MANUAL
ES
MANUAL PARA EL INSTALADOR Y EL USUARIO
PT
MANUAL DO INSTALADOR E UTILIZADOR
FELHASZNÁLÓ ÉS TELEPÍTŐ KÉZIKÖNYV
HU
RO
MANUAL DE INSTALARE ŞI UTILIZARE
PL
PODRĘCZNIK INSTALATORA I UŻYTKOWNIKA
SR
PRIRUČNIK ZA INSTALATERE I KORISNIKE

Advertisement

Table of Contents
loading

Summary of Contents for Beretta EXCLUSIVE X

  • Page 1 Installer and user manual EXCLUSIVE X INSTALLER AND USER MANUAL MANUAL PARA EL INSTALADOR Y EL USUARIO MANUAL DO INSTALADOR E UTILIZADOR FELHASZNÁLÓ ÉS TELEPÍTŐ KÉZIKÖNYV MANUAL DE INSTALARE ŞI UTILIZARE PODRĘCZNIK INSTALATORA I UŻYTKOWNIKA PRIRUČNIK ZA INSTALATERE I KORISNIKE...
  • Page 2 EXCLUSIVE X EXCLUSIVE X boiler complies with basic requirements of the following Directives: In some parts of the booklet, some symbols are used: - Regulation (EU) 2016/426 WARNING = for actions requiring special care and adequate preparation. - Efficiency directive: Article 7(2) and Annex III of directive 92/42/EEC - Electromagnetic compatibility directive 2014/30/EU - Low-voltage directive 2014/35/EU PROHIBITED = for actions THAT MUST NOT be performed. - Directive 2009/125/EC Ecodesign for energy-using appliances - Regulation (EU) 2017/1369 Energy labeling DHW functions refer only if a water tank is connected (accessory available on request).
  • Page 3: Warnings And Safety

    Exclusive X is a type C condensing wall-hung boiler that is able to operate as follows: During installation, inform the user that: CASE A: only heating with no external water tank connected. The boiler does not provide do- mestic hot water.
  • Page 4 EXCLUSIVE X ANTI-FREEZE SYSTEM The boiler is fitted as standard with an automatic anti-freeze system that activates when the temperature of the water in the primary circuit falls below 5°C. This system is always active and provides protection for the boiler up to an air temperature in the installation area of 0°C.
  • Page 5: Gas Connection

    ENGLISH In particular on the boiler display: dispositions. It is essential for the evacuation of the flue gases and the adduction of the - it is no longer possible to set the boiler OFF/WINTER/SUMMER status (it is set by the boiler's combustion air that only original pipes be used (except C6) and that the connection is made correctly as shown in the instructions provided with the flue gases accessories.
  • Page 6 EXCLUSIVE X The table shows the standard configurations allowed. 1 Bend 90° Ø 80 Air suction 4.5m pipe Ø80 chimney for ducting Ø 50 mm or Ø 60 mm 1 Bend 90° Ø 80 or Ø 80 mm 4.5m pipe Ø80 Flue gas discharge Reduction from Ø80 to Ø50 from Ø80 to Ø60...
  • Page 7: Draining The Heating System

    ENGLISH 2.10 Draining the heating system The maximum recirculated value allowed in wind conditions is 10%. Before draining, set the boiler to OFF and shut off the electrical supply setting the system's main switch to “off”. The maximum permissible pressure difference (25 Pa) between the combustion - Close the heating system's taps (if present).
  • Page 8 EXCLUSIVE X CONTROL PANEL (REC10CH) Boiler control panel REC10CH Confirm PLANT 18/05/2021 12:17 1.3 bar MENU STATE back= return to the previous screen cancel selection °C return to the main screen (press > 2 sec.) INFO HOT WATER TEMPERATURE - From the main screen they allow you to choose between the options: MENU, INFO, SET, STATE, PLANT.
  • Page 9 ENGLISH Structure of the MENU tree of the REC10CH DEFAULT VALUE FACTORY MINIMUM MAXIMUM ACCESS LEVEL VALUE VALUE NOTES VALUE MENU SETTINGS USER TIME & DATE USER DAYLIGHT SAVINGS TIME FUNCTION ACTIVE FUNCTION NOT ACTIVE FUNCTION ACTIVE USER LANGUAGE ENGLISH / ITALIANO / ... USER BACKLIGHT 5 min...
  • Page 10 EXCLUSIVE X DEFAULT VALUE FACTORY MINIMUM MAXIMUM ACCESS LEVEL VALUE VALUE NOTES VALUE MENU SP INCR LOW TEMP 0°C 0°C 6°C SERVICE DECR COOLING SP 0°C 0°C 10°C SERVICE PUMP DUTY CYCLE INSTALLER RESET CH TIMERS FUNCTION NOT ACTIVE FUNCTION NOT ACTIVE...
  • Page 11 ENGLISH DEFAULT VALUE FACTORY MINIMUM MAXIMUM ACCESS LEVEL VALUE VALUE NOTES VALUE MENU INSTALLER WATER TANK REMOVE WATER TANK INSTALLER INSTALLER: only if “only heating” WATER TANK TYPE confi guration SERVICE: only if “only heating” TANK FROST PROTECT 7°C 0°C 100°C confi...
  • Page 12 EXCLUSIVE X DEFAULT VALUE FACTORY MINIMUM MAXIMUM ACCESS LEVEL VALUE VALUE NOTES VALUE MENU BOOSTER DELTA TEMP 5°C 1°C 20°C INSTALLER INSTALLER OAT SENSOR TYP MINIMUM PUMP SPEED 100% INSTALLER MAXIMUM PUMP SPEED 100% 100% INSTALLER ENABLE ERROR HISTORY SERVICE...
  • Page 13 ENGLISH REC10CH MASTER: the heat request to the boiler is generated by the REC10CH MASTER that assumes the function of MACHINE INTERFACE - TYPE OF ZONE: this parameter allows you to specify the type of zone to be heated, it ANTI-CYCLE FUNCTION is possible to choose from among the following options: HIGH TEMPERATURE (factory setting)
  • Page 14: Weather Compensation

    EXCLUSIVE X The water tank retention time for anti-legionella varies according to the temperature value Using the REC10CH it is possible to set the selected thermoregulation curve: set in the ANTILEGIO TEMP parameter, as shown in the table: - select TECHNICAL...
  • Page 15 ENGLISH Vent cycle Adjusting the heating water temperature with an outdoor temperature sensor connected Each time that the boiler is powered, an automatic vent cycle is carried out lasting The outlet temperature value is automatically chosen by the system, which rapidly adjusts 6 min.
  • Page 16 EXCLUSIVE X SCREED HEATING FUNCTION NOT ACTIVE FUNCTION ACTIVE INSTALLER The screed heater function, when active, is signalled on the main screen by the scrolling message at the bottom of the SCREED HEATING FUNCTION IN PROGRESS - OUTLET TEMPERATURE page. The “screed heater” function lasts 168 hours (7 days) during which, in the zones configured as low temperature, a heating request is simulated with an initial zone outlet of 20°C, then increased in line with the table on the side.
  • Page 17 ENGLISH 4.14 Lights and faults For fault E060: the appearance of this error, on only heating models with water tank with The occurrence of an anomaly is indicated by the presence of the flashing icon on the probe connected, prevents DHW operation. main screen.
  • Page 18 4.18 Switching off for lengthy periods 1 - 10:30 18/11/2020 The long term non use of the Exclusive X boiler causes the following operations to be carried out: E030 - set the boiler to OFF - set the system’s main switch to “off”...
  • Page 19: Boiler Type

    SERVICE Then proceed with the reprogramming of the boiler, carrying out the operations described BOILER TYPE in the section “4.2 Programming the boiler”. Exclusive X 25R 4.21 Boiler configuration Exclusive X 35R The BOILER menu allows you to change the hydraulic configuration without necessarily having to go through a SYSTEM RESET operation.The HYDRAULIC CONFIG parameter can...
  • Page 20: Self-Calibration

    EXCLUSIVE X COMBUSTION SELF-CALIBRATION - Vacuum out any dirt residues inside the heat exchanger, being careful NOT to damage Function used by the after sales service to make an automatic combustion bend correction if the retarder insulating panel. the CO values (shown in the technical data) are outside the permitted range.
  • Page 21: Cleaning The Siphon

    ENGLISH Replacing of the burner insulation panel Maintenance of the ionisation electrode The detector electrode/ionisation probe play an important role in the boiler ignition phase and maintaining an efficient combustion; in this regard, if it is replaced, it must always be positioned correctly and the reference position indicated in the figure must be complied with.
  • Page 22: User Functions

    EXCLUSIVE X USER Depending on the type of application, some of the functions described in this manual might not be available. USER FUNCTIONS PLANT 18/05/2021 12:17 1.3 bar MENU STATE °C INFO HOT WATER TEMPERATURE 1 MENU DEFAULT VALUE FACTORY...
  • Page 23: Start Screen

    ENGLISH START SCREEN Main zone - Select STATE MAIN ZONE Upon ignition, the REC10CH might: - if the heating programming timing is not enabled: ZONE ON - ZONE OFF - request the setting of the time and date (see “11.1 Settings”) - if the heating programming timing is enabled: AUTO - MANUAL - HEAT OFF.
  • Page 24 EXCLUSIVE X 11 MENU - Select MENU (available only if the timer is SETTINGS or TIME SCHEDULE enabled (POR=1). HEATING THE PARAMETER WILL BE CHANGED MENU 78,0 °C SETTINGS CONFIRM CANCEL CONFIRM OR DELETE SELECTION Hot water TIME SCHEDULE With heating only boiler connected to a domestic hot water tank, the parameter refers to the temperature of the domestic water stored in the water tank.
  • Page 25 ENGLISH 12 PROGRAMMING TIMING Once the operation completed the display will show: Select the desired day. MAIN A table will be displayed indicating the day and the time frames already present. START THURSDAY 07:30 08:30 PLANT 11:30 13:30 12/04/2021 12:17 SELECT PERIOD TO DELETE 18:30...
  • Page 26 EXCLUSIVE X Once the operation completed the display will show: 1.ZONE1 1.ZONE1 1.ZONE1 09/04/2021 12:17 MAIN MENU MODE COMFORT COMFORT YOU ARE ACTIVATING MODE YOU ARE ACTIVATING MODE ENTER TIME DURATION IN HOURS ENTER TIME DURATION IN HOURS 01 : 00 SCHEDULE OF THURSDAY WILL BE COPIED ON THE °C...
  • Page 27: Technical Data

    ENGLISH 14 TECHNICAL DATA EXCLUSIVE X DESCRIPTION Rated heat input kW-kcal/h 20,00 (****)-17.200 32,00-27.520 32,00-27.520 Nominal heat output (80°/60°) kW-kcal/h 19,50-16.770 31,23-26.860 31,23-26.860 Nominal heat output (50°/30°) kW-kcal/h 21,32-18.335 34,37-29.556 34,37-29.556 Reduced heat input kW-kcal/h 3,60-3.096 5,00-4.300 4,90-4.214 7,00-6.020 4,90-4.214 7,00-6.020...
  • Page 28 EXCLUSIVE X EXCLUSIVE X PARAMETERS Lower Wobbe index (at 15°C-1013 mbar) MJ/m³S 45,67 70,69 Net Calorific Value MJ/m³S 34,02 Supply nominal pressure mbar (mm H2O) 20 (203,9) 37 (377,3) Supply minimum pressure mbar (mm H2O) 10 (102,0) PARAMETERS Burner: diameter/length...
  • Page 29 EXCLUSIVE X [EN] GENERAL SECTION 25 X R 35 - 40 X R 15.1 [EN] - Boiler operating elements Water gauge Air filter Ignition transformer Return NTC probe Drain valve Delivery NTC probe Fume analysis sample cap Gas nozzle Three-way valve (stepper)
  • Page 30 EXCLUSIVE X [EN] - Residual head of circulator (e.g. booster circulator)) is only active in the it is necessary to make the most of the 4 - EXCEPTIONAL USE OF A STANDARD heating function. The circulator always oper- boiler discharge head in order to ensure...
  • Page 31 EXCLUSIVE X blu (-) TSC2 F=3.15A F marrone (+) V Hv marrone rosa arancione E.R. arancione (SE) X3 X7 arancione (SE) rosa (OT+) nero (-) rosa (OT+) arancione (A) nero (TA) F1=4A T giallo (B) nero (TA) rosso (+24 Vdc)
  • Page 32 EXCLUSIVE X 15.8 [EN] Fumes exhaust configuration B23P-B53P Ø60-100 Ø80-125 Ø80-80 15.9 [EN] MAX LENGTH PIPES Ø 80 flue gas pipe length (m) air suction pipe length (m) Lunghezza tubo aspirazione aria (m) Maximum straight length (m) Pressure drop (m)
  • Page 33 EXCLUSIVE X Boiler control panel EN - REC10CH Confirm PLANT 18/05/2021 12:17 - Return to the previous page/cancel selection BACK 1.3 bar MENU STATE - Return to the main screen (press > 2 sec.) - From the main screen they allow you to choose between the options: MENU, INFO, SET, °C...
  • Page 36 Via Risorgimento, 23/A 23900 LECCO Italy info@berettaboilers.com www.berettaheating.com In order to improve its products, Beretta reserves the right to modify the characteristics and information contained in this manual at any time and without prior notice. Consumers statutory rights are not affected.