Beretta EXCLUSIVE C Series Installer And User Manual page 16

Hide thumbs Also See for EXCLUSIVE C Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
EXCLUSIVE
FRI
FRI
18/05/2013
MENU
MENU
INFO
INFO
HOT WATER TEMPERATURE
HOT WATER TEMPERATURE
HOT WATER ONLY
HEATING AND HOT WATER
- Through the REC10 it is possible to access, using the TECHNICAL
menu, a series of parameters that can be programmed to allow you to
personalise the operation of the boiler based on the type of system.
- Then set the parameters according to the desired operating modes.
5.2.1
Boiler configuration
- Access the technical parameters as explained in the section "4.1 Access
to the technical parameters" .
- Select PARAMETERS with the "up" and "down" keys, confirming the
selection.
INSTALLATION
WEATHER COMPENSATION
TERMOREGOLAZIONE
THERMOREGULATION
RANGE RATED
CALIBRATION
INSTALLER
INSTALLER
-
Select from among the following options with the "up" and "down",
keys, confirming the selection.
ANTI-CYCLE FUNCTION
TIMER OFF CH
RESET TIMERS CH
RESET CH TIMERS
DHW THERMOSTAT
DHW THERMOSTAT
INSTALLER
INSTALLER
-
ANTI-CYCLE FUNCTION
This parameter allows you to change the ANTI-CYCLE FUNCTION,
regarding the delay time introduced for re-igniting the burner in the face
of an off due to the heating temperature being reached. The factory
16
PLANT
PLANT
12:17
1.3 bar
STATE
STATE
42
°C
SET
SET
STATE
STATE
BOILER
BOILER
MAIN ZONE
MAIN ZONE
BOILER
BOILER
OFF
OFF
SUMMER
WINTER
TECHNICAL
TECHNICAL
INSTALLATION
PARAMETERS
PARAMETERS
RANGE RATED
CALIBRATION
PARAMETERS
PARAMETERS
PREHEATING
PREHEATING
setting for this parameter is 3 minutes and can be set to a value between
0 min and 20 min selecting the desired one with the "up" and "down",
keys confirming the selection.
ANTI-CYCLE FUNCTION
TIMER OFF CH
RESET CH TIMERS
-
This parameter allows you to reset the REDUCED HEATING MAXIMUM
OUTPUT TIMING, during which the speed of the fan is limited to 75%
of the maximum heating output that has been set, and the ANTI-CYCLE
FUNCTION. The factory setting for this parameter is FUNCTION NON
ACTIVE, select FUNCTION ACTIVE using the keys "up" and "down",
confirming the selection for resetting the timings.
RESET CH TIMERS
RESET TIMERS CH
FUNCTION NOT ACTIVE
FUNCTION NOT ACTIVE
FUNCTION ACTIVE
FUNCTION ACTIVE
INSTALLER
INSTALLER
- DOMESTIC HOT WATER THERMOSTAT
This parameter allows you to set the type of DOMESTIC HOT WATER
THERMOSTAT.
The factory setting for this parameter is RELATED, i.e. for domestic hot
water the boiler switches off at setpoint +5°C and restarts at setpoint
+4°C.
To select the ABSOLUTE values, where the boiler for domestic hot water
will still switch off at 65°C and restart at 63°C, use the keys "up" and
"down".
DHW THERMOSTAT
DHW THERMOSTAT
INSTALLER
INSTALLER
- PREHEATING
Setting PREHEATING = 1 the boiler's domestic hot water function
activates. This function keeps the water in the domestic hot water
exchanger hot, to reduce standby times when a request is made. When
the preheating function is enabled the symbol P comes on with a steady
light at the top with respect to the hot water icon. During burner ignition
following a preheating request, the symbol P starts flashing.
To deactivate the preheating function, set the parameter to PREHEATING
= 0, the symbol P switches off.
The function is not active when the boiler is OFF.
TERMOSTATI SAN
3
MIN
RELATED
RELATED
ABSOLUTE
ABSOLUTE
PREHEATING
PREHEATING
0

Advertisement

Table of Contents
loading

Table of Contents