Beretta EXCLUSIVE C Installer And User Manual

Hide thumbs Also See for EXCLUSIVE C:

Advertisement

Installer and user manual
EXCLUSIVE C
EN
INSTALLER AND USER MANUAL
ES
MANUAL DE INSTALACIÓN Y USO
RO
MANUAL DE INSTALARE SI UTILIZARE

Advertisement

Table of Contents
loading

Summary of Contents for Beretta EXCLUSIVE C

  • Page 1 Installer and user manual EXCLUSIVE C INSTALLER AND USER MANUAL MANUAL DE INSTALACIÓN Y USO MANUAL DE INSTALARE SI UTILIZARE...
  • Page 2: Range Rated

    EXCLUSIVE boiler complies with basic requirements of the Installer’s-user’s manual 3-28 following Directives: Boiler operating elements - Gas directive 2009/142/EC Electric diagrams - Efficiency directive: Article 7(2) and Annex III of directive 92/42/ Hydraulic circuit Circulator residual head - Electromagnetic compatibility directive 2014/30/EU - Low-voltage directive 2014/35/EU - Directive 2009/125/EC Ecodesign for energy-using appliances - Directive 2010/30/EU Indication by labelling of the consumption of energy by energy-related products - Delegated Regulation (EU) No. 811/2013...
  • Page 3: Warnings And Safety

    The EXCLUSIVE boilers have a new ACC (Activate Combustion Control) valve. system. This new control system, developed by Beretta, ensures functionality, The seal of the condensate drainage connection line must be secure, efficiency and low emissions under any conditions. and the line must be fully protected against the risk of freezing (e.g.
  • Page 4: Installation Regulations

    EXCLUSIVE Electrical wiring Under the safety valve, install a water collecting funnel with the - fig. 10-11 corresponding discharge in the event of leaks due to the overpressure Low voltage connections of the heating system. The domestic hot water circuit does not need a Carry out the low voltage connections as follows: safety valve, but make sure that the pressure of waterworks does not - use the external cable box supplied as standard...
  • Page 5 ENGLISH The boiler is a C-type appliance (with airtight chamber), and must therefore Twin pipes ø 80 with ducting Ø50 - Ø60 - Ø80 (fig. 15a) have a safe connection to the flue gas discharge pipe and to the combustion Thanks to the boiler characteristics, a flue gas discharge pipe ø...
  • Page 6: User Interface

    EXCLUSIVE 3.12.1 User interface COMPONENT Ø 50 Linear equivalent in metres Ø80 (m) The user interface is made up of a button (A), a two-coloured red / green Bend 45° Ø 50 12,3 LED (B) and four yellow LEDs (C) arranged in a row. Bend 90°...
  • Page 7: Changing The Operating Mode

    ENGLISH 3.12.6 Changing the operating mode IMPORTANT If the 3 (5 metres) or 4 (4 metres) curves are set the bypass must be replaced In normal operating conditions the circulator works with the factory settings with the one supplied, following the procedure indicated below: or the last settings carried out.
  • Page 8: Control Panel (Rec10)

    EXCLUSIVE CONTROL PANEL (REC10) The REC10 remote control has the function of machine interface, displaying the system and providing access to the parameters. The middle of the main screen displays the temperature of the domestic hot water probe, unless there is a heat request is in progress, in this case the delivery temperature of the boiler at that particular time is displayed.
  • Page 9 ENGLISH DEFAULT VALUE MINIMUM MAXIMUM ACCESS LEVEL MENU FACTORY SET VALUE VALUE NOTES VALUE SETTINGS USER TIME & DATE USER LANGUAGE ITALIANO / ENGLISH USER BACKLIGHT 5 min 1 min 15 min USER TIME SCHEDULE USER USER MAIN Only if POR = 1 USER ZONE1 Only if POR = 1...
  • Page 10 EXCLUSIVE MINIMUM MAXIMUM ACCESS LEVEL DEFAULT VALUE VALUE VALUE NOTES VALUE FACTORY SET PARAMETERS INSTALLER TIMER OFF CH 3 min 0 min 20 min INSTALLER HYST ON HIGH TEMP 5°C 2°C 10°C SERVICE HYST OFF HIGH TEMP 5°C 2°C 10°C SERVICE HYST ON LOW TEMP 3°C...
  • Page 11 ENGLISH DEFAULT VALUE MINIMUM MAXIMUM ACCESS LEVEL FACTORY SET VALUE VALUE NOTES VALUE SWEEPER INSTALLER ACTIVATE FUNCTION INSTALLER DEACTIVATE FUNCTION INSTALLER MAX SPEED INSTALLER RANGE RATED SPEED RANGE RATED INSTALLER MIN SPEED INSTALLER CHANGE FAN SPEED Current speed INSTALLER F. NOT ACTIVE / DAILY FUNCTION / ANTI-LEGIONELLA WEEKLY FUNCTION INSTALLER...
  • Page 12 EXCLUSIVE DEFAULT VALUE MINIMUM MAXIMUM ACCESS LEVEL FACTORY SET VALUE VALUE NOTES VALUE INSTALLER ADD HEAT PUMP Only if heat pump not configured HEAT PUMP INSTALLER INSTALLER REMOVE HEAT PUMP Only if heat pump configured USE FREE CONTACTS / USE BUS USE BUS USE BUS USE FREE CONTACTS...
  • Page 13: Preliminary Checks

    First ignition is carried out by competent personnel from an authorised Technical Assistance Service Beretta. - select MENU on the initial page of the REC10 and press the key Before starting up the boiler, check:...
  • Page 14: Boiler Configuration

    EXCLUSIVE PARAMETERS PLANT 18/05/2013 12:17 1.3 bar MENU STATE TIMER OFF CH RESET TIMERS CH °C DHW THERMOSTAT PREHEATING INFO INSTALLER HOT WATER TEMPERATURE TIMER OFF CH This parameter allows you to change the TIMER OFF CH, regarding the delay time introduced for re-igniting the burner in the face of an off due to the heating temperature being reached.
  • Page 15 ENGLISH - PREHEATING - Select the desired heating zone and then choose from among the options Setting PREHEATING = 1 the boiler’s domestic hot water function with the “up” and “down” keys, confirming the selection: activates. This function keeps the water in the domestic hot water exchanger hot, to reduce standby times when a request is made.
  • Page 16: First Commissioning

    EXCLUSIVE - using the “up” and “down” keys select PROGRAMME TIMER confirming Using the REC10 it is possible to set the value of the following parameters: the selection BUILDING TYPE It is indicative of the frequency with which the value of the calculated MENU outdoor temperature for thermoregulation is updated, a low value for this value will be used for buildings that have little insulation.
  • Page 17 ENGLISH The vent cycle can be interrupted beforehand by removing the cap - Adjust the room thermostat to the desired temperature (~20°C) or, if the from the instrument panel and pressing the combustion analysis system is equipped with a chronothermostat or programmable timer or button SW1 or else from the TECHNICAL menu of the REC10 in the REC10 set as an ambient regulator, ensure that the thermostat or timer following way:...
  • Page 18 EXCLUSIVE To deactivate the preheating function, set the parameter to PREHEATING = 0, the symbol “P” switches off. BOILER The function is not active when the boiler is OFF. SUMMER HEATING WINTER PREHEATING Adjusting the heating water temperature without an outdoor temperature sensor connected When there is no outdoor temperature sensor, the boiler operates at a fixed-point, the HEATING setpoint in this case can be set selecting SET on the main screen of the REC10 and selecting the desired value...
  • Page 19: Gas Conversion

    ENGLISH 5.10 Screed heating function TIME TEMPERATURE For a low temperature system the boiler has a “screed heating” function 20°C that can be activated in the following way: 22°C - set the status of the boiler to OFF 24°C 26°C BOILER 28°C 30°C...
  • Page 20: Combustion Check

    EXCLUSIVE - select LPG Wait for the burner to ignite. The boiler will operate at maximum heating output and it will be possible to GAS TYPE regulate the combustion. - Insert the analyser probes in the specific positions on the air distribution box, after removing screw (A) and cap of the flue gases analysis socket (B).
  • Page 21 ENGLISH EXCLUSIVE 30C n Curva portata termica - giri ventilatore Caldaia Vision+ 28C PLUS HTG curve (Qnheating) 8400 8000 RANGE RATED 7600 7200 6800 6400 5100 6000 5600 5200 4800 4400 4000 3600 3200 2800 2400 2000 1600 - once the desired power is set (maximum heating) note the value onto the 1200 supplied self-adhesive label.
  • Page 22 EXCLUSIVE If the attempts to reset the boiler do not work, contact the Technical - select CONFIRM to confirm the rest of the flue gases probe meter or else Assistance Centre. CANCEL to cancel the operation For fault E041 If the pressure drops below the safety pressured of 0.3 bar the boiler displays the fault code “E041 - WATER TRANSDUCER PRESS OK TO FILL THE SYSTEM”...
  • Page 23 ENGLISH Boiler faults list ERROR DESCRIPTION OF TYPE ERROR MESSAGE RED LED GREEN LED CODE OF ALARM E010 flame lockout/ACF electronic fault definitive flashing E011 extraneous flame transitional 0.2 sec. on/0.2 off flashing E020 limit thermostat definitive 0.5 sec. on/0.5 off E030 fan fault definitive...
  • Page 24 EXCLUSIVE 5.16 Alarm history The activation of the ANTI-FREEZE function is indicated by a scrolling message on the foot of the REC10 display. The ALARM HISTORY function is automatically enabled only after the - circulator anti-locking: the circulator activates every 24 hours of machine has been powered up for at least 2 consecutive hours, during stoppage for 30 seconds.
  • Page 25 ENGLISH - select CONFIRM to conform the system reset or else CANCEL to cancel - setting the operating mode of the REC10: the operation. MASTER: select this option when the REC10 is also a MACHINE INTERFACE. - configuration selection: FROM AKM: to reset the current boiler configuration on REC10 MASTER and finish the operation NEW: to set a new system configuration restoring the factory setting of CONFIRM...
  • Page 26 EXCLUSIVE Continue with the configuration as follows: TECHNICAL - access the technical parameters as explained in the section “4.1 Access to the technical parameters” , using the password SERVICE PARAMETERS - select PARAMETERS with the “up” and “down” keys, confirming the selection VENT CYCLE - next change the following parameters:...
  • Page 27: Maintenance

    ENGLISH 5.24 Maintenance Periodic maintenance is an “obligation” required by law and is essential to the safety, efficiency and lifetime of the boiler. It allows for the reduction of consumption, polluting emissions and keeping the product reliable over time. Before starting maintenance operations: - carry out the analysis of the combustion products to check the operating status of the boiler, then cut off the electrical supply setting the system’s main switch to “off”...
  • Page 28: User Guide

    EXCLUSIVE USER GUIDE Depending on the type of application, some of the functions described in this manual might not be available. CONTROL PANEL REC10 The REC10 remote control unit has the function of a machine interface, as it displays the system’s settings and allows the parameters to be accessed.
  • Page 29: Start Screen

    ENGLISH START SCREEN Boiler This function can be selected in order to set the boiler’s status, by choosing Upon ignition, the REC10 might: one of the following options: - request the setting of the time and date (see paragraph “12.1.1 Time - OFF and date”...
  • Page 30 EXCLUSIVE 10.2 Hot water 9.2.1 If ON is selected, the zone requests are met. Press the “up” and “down” keys to change the boiler’s domestic hot water setpoint. Press “ok” to confirm the selection. 9.2.2 AUTO Press “back/cancel” to return to the screen without making any If AUTO is selected, the zone requests will be managed based on a selection.
  • Page 31 ENGLISH 11 INFO TIME & DATE The INFO function can be used to display a series of data regarding the system. ENTER TIME AND DATE ATTENTION - The displayed data cannot be modified. Press the “up” and “down” keys to go through the list of information available, in this order: - SCREED HEATER OPERATING HOURS 18 / 11 / 2013...
  • Page 32 EXCLUSIVE MAIN SCHEDULE 18/11/2013 12:17 START THURSDAY 07:30 08:30 MAIN 11:30 13:30 PERIOD 18:00 22:30 ENTER ZONE 1 END TIME 15:00 ZONE 2 14:00 SELECT THE ZONE USE THE ARROWS TO MODIFY In order to confirm that the operation has been completed successfully, the 13 PROGRAMMING TIMING display will show the table with the new time frame flashing.
  • Page 33 ENGLISH In order to confirm that the operation has been completed successfully, the MAIN display will show the table with the selected time frame flashing just before deleting it from the table. START THURSDAY 07:30 08:30 11:30 13:30 MAIN 18:00 22:30 ENTER START...
  • Page 34 EXCLUSIVE 14 FAULTS PLANT 18/05/2013 12:17 If any faults should occur, a screen will appear on the display indicating 1.3 bar MENU STATE the relative error code and a brief alphanumeric description of the same. Pressing the “back/cancel” button it is possible to return to the main screen, where a fault is signalled by this flashing icon °C The user can return to the fault description screen by using the “up”...
  • Page 35: Reset Function

    ENGLISH 14.1 Reset function For fault E041 If the pressure drops below the safety threshold of 0.3 bar the boiler displays In order to reset the boiler’s operation in the event of a fault, it is necessary the fault code “E041 - WATER TRANSDUCER PRESS OK TO FILL THE to access the fault description screen.
  • Page 36: Technical Data

    EXCLUSIVE TECHNICAL DATA EXCLUSIVE DESCRIPTION 25C n 30C n Heating Rated heat input 18,00 24,00 kcal/h 15.480 20.640 Nominal heat output (80°/60°) 17,55 23,40 kcal/h 15.093 20.124 Nominal heat output (50°/30°) 19,06 25,39 kcal/h 16.393 21.837 Reduced heat input 3,70 5,20 4,30 6,00...
  • Page 37: Hydraulic Connections

    ENGLISH EXCLUSIVE DESCRIPTION 25C n 30C n Gas pressure Nominal methane gas pressure (G20) mbar mbar Nominal liquid gas LPG pressure (G31) mbar Hydraulic connections CH input - output Ø 3/4” 3/4” DHW input-output Ø 1/2” 1/2” Gas input Ø 3/4”...
  • Page 38 EXCLUSIVE EXCLUSIVE PARAMETERS METHANE GAS (G20) LPG (G31) Lower Wobbe index (at 15°C-1013 mbar) MJ/m³S 45,67 70,69 Net Calorific Value MJ/m³S 34,02 Supply nominal pressure mbar (mm H 20 (203,9) 37 (377,3) Minimum supply pressure mbar (mm H 10 (102,0) 25C n Number of diaphragm holes n°...
  • Page 39 ENGLISH EXCLUSIVE 25C n Seasonal space heating energy efficiency Water heating energy efficiency class class Parameter Symbol Value Unit Parameter Symbol Value Unit Seasonal space heating energy Rated heat output Prated ηs efficiency For boiler space heaters and boiler combination heaters: For boiler space heaters and boiler combination heaters: useful heat output useful efficiency...
  • Page 40 EXCLUSIVE [EN] - Functional elements of the 10 Conveyor 22 Expansion vessel 11 Fan 23 Main heat exchanger appliance 12 Mixer 24 Pressure transducer Pressure gauge 13 Ignition transformer 25 Gas diaphragm Drain valve 14 Flue gas exhaust 26 Gas valve 3-way valve motor 15 Degassing unit pipe 27 Domestic hot water NTC probe...
  • Page 41 EXCLUSIVE “L-N” POLARITY IS RECOMMENDED...
  • Page 42 EXCLUSIVE [EN] - Multiwire wiring diagram Blu=Blue/Marrone=Brown/Nero=Black/Rosso=Red/Bianco=White/ Low temperature thermostat Viola=Violet/Rosa=Pink/Arancione=Orange/Grigio=Grey/Giallo=Yellow/ Outdoor temperature sensor Verde=Green Open therm SBOL Not used A = Gas valve X1 - X2 Not used B = 230V auxiliary Pump C = Not used PWM signal D = Voltage free contact input Gas valve operator AKM0X...
  • Page 43 EXCLUSIVE [EN] - Residual head of circulator Bear in mind that the boiler will operate correctly To this end, the boiler is fitted with an automatic The residual head for the heating system is if there is sufficient water circulation in the heat by-pass which is designed to ensure water flow represented in graphic 1, according to the flow exchanger.
  • Page 44 EXCLUSIVE boiler support plate (F) [EN] A = condensate drain B = water - gas [EN] heating return 3/4” M heating delivery 3/4” M gas connection 3/4” M AC hot water 1/2” M cold water 1/2” M measured in mm distances in mm...
  • Page 45 EXCLUSIVE 1-2-3-4 (- A B +) Bus 485 Room thermostat (contact without voltage) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TBOL Not used - A B + OT+ SBOL X1 TA TBOL TBT SE 9-10...
  • Page 46 EXCLUSIVE chimney for ducting Ø 60 mm or Ø 50 mm 90° bends Ø 80 mm 4,5m Ø 80 mm 4,5m Ø 80 mm 90° bend Ø 60 mm Ø 50 mm or Ø 80 mm Ø 80-60 mm or Ø...
  • Page 47 EXCLUSIVE MAX LENGTH PIPES Ø 80 + Ø 80 Caldaia Exclusive 25C n lunghezza massima tubi ø 80 mm EXCLUSIVE 25C n 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 Lunghezza tubo aspirazione aria (m) air suction pipe length (m) Caldaia Exclusive 30C n lunghezza massima tubi ø...
  • Page 48 Fax +39 0341 277263 info@berettaboilers.com www.berettaboilers.com In order to improve its products, Beretta reserves the right to modify the characteristics and information contained in this manual at any time and without prior notice. Consumers statutory rights are not a ected.