Page 1
EXCLUSIVE C.A.I. R.A.I. MIX C.S.I. MIX R.S.I. INSTALLER AND USER MANUAL MANUEL D’INSTALLATION ET D’UTILISATION MANUAL DE INSTALACIÓN Y USO MANUAL PARA INSTALAÇÃO E USO TELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKÖNYV MANUAL DE INSTALARE SI UTILIZARE...
Page 2
• Directive rendements 92/42/CEE • Directive compatibilité électromagnétique 2004/108/CE • Directive basse tension 2006/95/CE et peut donc être estampillée CE La caldera EXCLUSIVE es conforme a los requisitos esenciales de las siguientes Directivas: • Directiva gas 2009/142/CE • Directiva rendimientos 92/42/CEE •...
Page 3
C.A.I. - MIX C.S.I. R.A.I. - MIX R.S.I. This handbook contains data and information for both users and installers. In detail: - the chapters entitled “Installing the boiler, Water connections, Gas connection, Electrical connection, Filling and draining, Evacuating products of combustion, Technical data, Programming parameters, Gas regulation and conversion” are intended for installers;...
Page 4
Este livrete inclui dados e informações destinados quer ao usuário quer ao instalador. Especifi cadamente: - os capítulos “Instalação da caldeira, Conexões hidráulicas, Conexão gás, Ligação eléctrica, Enchimento e esvaziamento, Evacuação dos produtos da combustão, Dados técnicos, Programação parâmetros, Regulação e Transformação gás”...
Exclusive MIX C.S.I. is a C-type wall-mounted boiler for heating and promptly inform the Technical Assistance Service and producing domestic hot water; Exclusive MIX R.S.I. is a C-type - C.A.I.-MIX C.S.I.: he/she must check from time to time to make...
Support plate and integrated pre-installation template are provided Gas and/or water pipes may not be used to earth electrical equipment. for with the boiler (fi g. 2). Mounting instructions: The installer is responsible for making sure that the ap- • fi x the boiler support plate (F) with the template (G) to the wall pliance has an adequate earthing system;...
Page 7
Maximum length concentric ducts ø 60-100 26 MIX C.S.I. FUMES EXHAUSTION AND BURNING AIR SUCTION (MIX C.S.I. - MIX R.S.I.) EXHAUSTION CONFIGURATIONS (fi g. 7) Boiler is homologated for the following exhaustion confi gurations: C12-C12x Concentric wall exhaustion. Pipes can separately start from boiler, but outlets must be concentric or close enough to be subject to similar wind conditions (within 50 cm) Concentric exhaustion in common chimney (suction and...
START-UP AND OPERATION (C.A.I. - MIX C.S.I.) The boiler produces heating and domestic hot water. The control panel (fi g. 13) contains the main boiler control and management functions. Description of commands Heating water temperature selector: sets the heating water temperature.
Page 13
Switching on Adjusting heating water temperature Turning the selector A (fi g. 18), after having positioned the selector Switch on the boiler as follows: - access the gas tap through the slots in the cover located in the mode on winter or winter comfort , it is possible to regulate lower part of the boiler...
Working the boiler If this condition occurs it means that the system is incorrectly pressurised though the boiler will continue to work regularly. Press Adjust the ambient thermostat to the required temperature (approx. the circuit fi lling button to start-up the fi lling sequence. 20 °C).
Info 2 shows circuit pressure (fi g. 31) S.A.R.A. BOOSTER function If the “winter comfort” mode is selected, the S.A.R.A. Booster fun- ction is activated for the heating circuit and reaches the required ambient temperature more quickly. DOMESTIC HOT WATER PRE-HEATING function If the “winter comfort”...
Resetting faults Wait for about 10 seconds before resetting operating conditions. PROGRAMMING PARAMETERS Then proceed as follows: This boiler incorporates a new generation of electronic boards that, 1) Viewing just the symbol by setting/modifying operating parameters, allow the boiler to be disappears, it means that an operating fault has been personalised to satisfy various system and/or user requirements.
Page 17
C.A.I.: programmable parameters N° DESCRIPTION PARAMETERS UNIT OF DEFAULT PARAMETERS PAR. MEASURE (setted in factory) (setted by techn. assist. centre) GAS TYPE 1 Methane 2 LPG 3 Methane France INSULATION LEVEL OF BUILDING (+) (*) DHW MODE 0 (OFF) 1 (Instantaneous) 2 (Mini-tank) 3 (External water-tank with thermostat) 4 (External water-tank with sensor)
Page 18
START-UP AND OPERATION (R.A.I. - MIX R.S.I.) This boiler is able to operate in different conditions: Depending on the type of installation selected, it is necessary to set the parameter “domestic hot water mode”. This operation CASE A) only heating must be performed by a Technical Service Centre when star- CASE B) only heating with external water tank connected, ting-up the boiler.
Page 19
Switching on Switch on the boiler as follows: - access the gas tap through the slots in the cover located in the lower part of the boiler - open the gas tap by turning it anti-clockwise (fi g. 47) - power the boiler. Fig.
Page 20
Working the boiler Boiler functions Adjust the ambient thermostat to the required temperature (approx. Filling the circuit 20 °C). If there is a demand for heating water, the boiler starts If circuit pressure reaches 0.6 bar, the pressure value fl ashes and the symbol is shown on the display (fi...