ETAS
7.4
Environmental Conditions
Item
Temperature range (operation)
Temperature range (storage)
Relative humidity (non-condensing)
Operating altitude
Contamination level
Degree of protection
7.5
Power Supply
Parameter
Permanent power
supply (car
battery)
Cranking voltage
Standby current
Operating current I
Power consump-
tion
Power consump-
tion
1)
The FETK-S1.1 implements reverse voltage protection in the same range
and may be used only with central load dump protection.
24 V vehicles require U
12 V vehicles don't require special disturbing pulse reductions.
NOTE
The FETK-S1.1 will accept permanent power supply voltage dips (for addi-
tional details of 3 V low voltage operation, see ISO standard 16750).
FETK-S1.1 - User's Guide
Characteristics
- 40 °C to +110 °C/ - 40 °F to +230 °F
0 °C to +50 °C/ - 18 °F to +122 °F
0 to 95%
max. 5000 m/ 16400 ft
2
Determined by installation in ECU
Symbol
Condition
U
Vehicle usage
Batt
U
< 3 seconds
Batt
I
U
= 12 V;
STBY
Batt
ECU off;
no load from ECU;
T = 20 °C
U
= 12 V;
Batt
Batt
no load from ECU;
T = 20 °C
P
U
= 12 V;
Batt
Batt
I = 0 mA at pin
ECU_SBRAM;
T = 20 °C
P
U
= 12 V;
Batt
Batt
I = 500 mA at pin
VDDSTBY [1.25 V];
I = 80 mA at pin
VDDPSTBY;
T = 20 °C
disturbing pulse reduction to 12 V vehicle system.
Batt
Technical Data
Min
Typ
Max Unit
1)
6.0
12
36
[all values +/-0%]
3
10
16
25
50
95
170
1.14
2.4
V
V
mA
mA
W
W
39