Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
Program codes or program control sequences that are created or changed via ETAS products, as well as all types of data obtained through the use of ETAS prod- ucts, must be checked for their reliability and suitability prior to use or distribution.
Shut down a damaged product immediately. The product cannot be repaired. Dispose of the product properly. Do not open or alter the product. Only ETAS may make changes to the product.
If the firmware update is not completed successfully, try it again. If a new firmware update is not possible and the product is not functional, send the product to ETAS. 1.3.3 Electrical Connection...
2. Remove all cables from the product. 1.3.4 Cables and Accessories Cables - Only use ETAS cables, cables recommended by ETAS or other cables certi- fied for the application. - Route the cables such that they are protected against abrasion, damage, deformation and kinking.
Order number of the product (example) SN: yyxxxxx Serial number (7-digit) XXXX/YY Product version ZZZZ Year of manufacture ETAS GmbH,... Manufacturer's address NOTE For symbols and product information one or several adhesive labels can be used. ETAS FETK-T1.1 | User Guide...
1.6.1 CE Declaration of Conformity (European Union) With the CE mark attached to the product or its packaging, ETAS confirms that the product corresponds to the applicable product-specific European Directives. The CE Declaration of Conformity for the product is available upon request.
Some products from ETAS GmbH (e.g. modules, boards, cables) use components with substances that are subject to declaration in accordance with the REACH regulation (EU) no.1907/2006. Detailed information is located in the ETAS download center in the customer infor- mation "REACH Declaration" (www.etas.com/Reach). This information is continu- ously being updated.
Product Variants Existing product variants are the FETK-T1.1A and the FETK-T1.1B Interface Board (FETK = Emulator Test Probe) for the ETAS ES89x ECU and Bus Interface Modules for adaptation to different microcontroller variants. This document references the "FETK-T1.1" product family for common hints or system requirements and other details or gives dedicated information for differences of FETK-T1.1A and FETK-...
15 | Introduction To access the ECU the FETK-T1.1 has to be connected via ES89x modules. The system can be used for high-speed Measurement, Calibration and ECU flash programming. Support of high-speed and high band width applications e.g. func- tional prototyping - bypass depends on the functionality of the connected mod- ules.
- “ETK Tools” update to support ETAS software tools (INCA, XCT) - Firmware update (programming of the logic device) through HSP software service packs; removal of FETK or ECU is not necessary - Mounting the FETK-T1.1 via heat spreader directly to the ECU housing is rec- ommended - Heat distribution - Temperature range suitable for automotive application For more technical data on the FETK-T1.1 consult the chapter “Technical Data”...
FETK-T1.1 interface. This process enables adjustments of parameters, characteristic lines and maps through the calibration and development system. Using a trace interface, the FETK-T1.1 can aquire measurement data and send the measured data to the PC. ETAS FETK-T1.1 | User Guide...
Power supply ECU Interface The FETK-T1.1 is connected via connectors CON1, CON2, and CON4 to the ECU with three adapter cables (refer to Fig. 3-2 on page 18). The pin definition depends on the application and the microcontroller type. In general, the ECU interface con-...
The FETK is suitable for 12 V and 24 V systems. In 24 V systems the low dump capa- bility is reduced. The FETK-T1.1 will also accept voltage drops down to 3 V, for a maximum duration of 15 ms (for additional details of low voltage operation, see ISO standard 16750).
It's not possible to monitor VDDSBFRAM, only. NOTE The FETK-T1.1 only allows switching between reference page and working page if there is a valid voltage at the sense pin and the working page has been initialized by the calibration and development system.
21 | Hardware Description Status LEDs There are three LEDs displaying the operating status of the FETK-T1.1 (Fig. 3-5 on page 21). i b a=ÖêÉÉå i b a=êÉÇ i b a=óÉääçï Fig. 3-5 Status LEDs State Definition FETK-T1.1 is supplied with power and active (i.e. the ECU is switched on or the ETAS calibration and development system is connected and ready to communicate with the FETK-T1.1)
ECU software directly as general-purpose RAM. It is recommended that the ED RAM is permanently pow- ered by the FETK-T1.1 or ECU and shall not be reseted by the ECU, if the FETK-T1.1 signals a permanently powering of the ED RAM during handshake.
3.7.2 Measurement Data Access The FETK-T1.1 is a serial FETK, so all data to be measured is located in the ECU memory. It can be read out by the FETK-T1.1 using the DAP interface in two ways: - Trace measurement using the Aurora trace interface - Read accesses using the DAP interface 3.7.2.1...
3.10.2 Triggering via Trace Interface The FETK-T1.1 provides support for up to 255 data trace triggers. The trace triggers are defined within a section of RAM covered by a trace window. Both the trace win- dow and trace triggers are defined in the FETK’s configuration and/or A2L file. A write by the microcontroller software to a trace trigger location causes a trace trigger.
25 | Hardware Description - up to 255 value-based trace trigger are supported. NOTE It is not possible to use the FETK-T1.1 configured with trace triggers and a debug- ger with program / data trace simultaneously. 3.10.3 Pinless Triggering 3.10.3.1 Startup Handshake The COMDATA trigger register is used to generate an FETK startup handshake.
ECU is in reset. NOTE The reset signal /PORST can be hold or pulled low while the FETK-T1.1 is booting depending on the use the adapter ETAM8A or the adapter ETAM8B (see chapter “ETAM8 Adapter” on page 62). The FETK-T1.1 has to be configured in the XCT tool according to the needed reset signal characteristic during FETK-T1.1 standby.
Preparing the ECU Housing 1. Drill four holes in the ECU housing. NOTE Use the “FETK-T1.1 Dimensions - Top View” on page 51 as a drilling template to prepare the ECU housing with machined holes aligning with FETK-T1.1 hole pattern.
Page 29
Attaching the FETK-T1.1 to the ECU Housing Fig. 4-2 Attaching the FETK-T1.1 to the ECU 1. Align the threaded drill holes of the FETK-T1.1 to the openings in the ECU housing. 2. Insert the screws into the holes in the ECU housing.
1. Use thread locking fluid to lock the four nuts, The FETK-T1.1 and the ECU housing are now connected mechanically. Connection to the ECU For connecting the FETK-T1.1 to the ECU three FETK adapter cables are recom- mended: - at CON1 adapter cable ETAM8A or ETAM8B...
Page 31
31 | Installation Fig. 4-5 FETK-T1.1 Connection to the ECU ETAS FETK-T1.1 | User Guide...
Gigabit Ethernet interfaces of the ES89x ECU Interface Module. 4.3.2 Power Supply The FETK-T1.1 needs a permanent power supply (refer chapter “Power Supply” on page 19). WARNING Risk to life from electric shock If an unsuitable power supply is used, this may generate a hazardous electrical voltage.
W irin g ECU G N D FETK EC U V ehicle C onnector Battery EC U Fig. 4-7 FETK-T1.1 Power Supply wiring with CBAM300.3 Cable Cable Gland Serial ETK Interface Connector Cable CBAM320.1 Cable CBAM320.1 E.g. Cable CBE260 Vehicle Power Supply...
35 | Installation 4.3.2.3 Isolated Power Supply inside ECU The FETK-T1.1 does not require a galvanically isolated power supply. For special applications ETAS can offer a isolated power supply unit. Power Supply Connector Isolated Power Supply Permanent Supply Input Cable ETAM 2 4,8 V«...
/ FETK is checked for the appropriate configuration. If necessary, the ETK / XETK / FETK will be configured appropriately to the corre- sponding project. Configuration Parameter The XCT provides support concerning hardware configuration parameters and their possible values. ETAS FETK-T1.1 | User Guide...
Page 37
The XCT help window opens. 3. Choose Reference to User Interface > (X)ETK Hardware Configuration Parameters. 4. Choose the topic FETK-T1.1. The topic FETK-T1.1 contains information about the FETK-T1.1 hardware configuration parameters and their possible values. ETAS FETK-T1.1 | User Guide...
• Mechanical Dimensions ..........51 System Requirements 6.1.1 ETAS Compatible Hardware ETAS Hardware: ES89x ECU Interface Modules 6.1.2 PC with one Ethernet Interface A PC with one open Ethernet interface (1 Gbit/s) with RJ-45 connection is required to connect the ES89x module.
6.2.1 Data Emulation Memory and Microcontroller Support The FETK-T1.1 uses a portion of or up to the entire size of the ED RAM, to emulate data in internal flash. The following table lists the supported microcontrollers, the size of the ED RAM, and states if the ED RAM is capable of being powered using a standby supply.
ECU the max. ambient temperature is assumed to be 105 °C at 1 m/s airflow. The power dissipation of the FETK-T1.1 will be max. 5.2 Watt. NOTE It is recommended to mount the FETK-T1.1 via the heat spreader directly to the ECU housing. ETAS FETK-T1.1 | User Guide...
58 V DC, e.g.(Littelfuse 0997002.WXN) The FETK-T1.1 implements reverse voltage protection in the same range and may be used only with central load dump protection. 24 V vehicles require U disturbing pulse reduction to 12 V vehicle system.
Batt NOTE The reset signal /PORST can be hold or pulled low while the FETK-T1.1 is booting depending on the use the adapter ETAM8A or the adapter ETAM8B (see chapter “ETAM8 Adapter” on page 62). The FETK-T1.1 has to be configured in the XCT tool according to the needed reset signal characteristic during FETK-T1.1 standby.
NOTE DAP timing parameters in this chapter refer to the DAP interface (CON1) of the FETK-T1.1. The DAP wiring to the ECU (ETAM8) must be taken account addition- ally. All timings are measured at a reference level of 1.5 V. Output signals are mea- sured with 20 pF to ground and 50 ...
Data1-P Input Do not use Data0-N Input Aurora data Signal Ground Signal Ground Data2-P Input Do not use Signal Ground Data2-N Input Do not use Clock-N Output Aurora clock Signal Ground Clock-P Output Aurora clock ETAS FETK-T1.1 | User Guide...
Power Supply Connector CON4 Signal Direction Comment VDDPSTBY Output Permanent power supply of ECU DAP Inter- (3.3 V supply) face, 3.3 V VDDSTBY Output Permanent power supply of ECU EDRAM, 1.30 (1.30 V supply) Input Power Ground ETAS FETK-T1.1 | User Guide...
See chapter 4.3 on page 32 for details on wiring the ECU interface adapt- ers. NOTE We recommend to use ETAS cables or any other cables certified by the standards for the application. Adhere to the maximum permissible cable lengths! NOTE Application-specific cables are available from ETAS.
Shield ECU housing 7.3.3 Temperature Range Condition Temperature Operating temperature -40 °C to +125 °C 7.3.4 Tightness Condition IP Code PG9 screwing IP67 7.3.5 Ordering Product Length Order Number CBAM300.3-0m6 0.6 m F 00K 112 469 ETAS FETK-T1.1 | User Guide...
White FETK 7.4.3 Temperature Range Condition Temperature Operating temperature -40 °C to +125 °C 7.4.4 Tightness Condition IP Code PG8 screwing IP67 7.4.5 Ordering Product Length Order Number CBAM320.1-0m6 0.6 m F 00K 109 299 ETAS FETK-T1.1 | User Guide...
Gbit Ethernet cable, e.g. CBE260 CON2 White FETK CON3 Shield to ECU housing 7.5.3 Temperature Range Condition Temperature Operating temperature -40 °C to +125 °C 7.5.4 Ordering Product Length Order Number CBAM340.1-0m6 0.6 m F 00K 109 302 ETAS FETK-T1.1 | User Guide...
(not included in the delivery). NOTE The Lemo Spanner DCH.91.161.PA is not included in the cable delivery, It need to be ordered separately. For detailed information on mounting accessories con- tact ETAS technical support. ETAS FETK-T1.1 | User Guide...
For mounting the cable, cut a PG9 thread into the ECU housing. For thin walled housings use a nut SM-PE 9. It is available from Lapp (order number: 52103210). 7.7.2 Dimensions Fig. 7-9 CBAM305.1-0m6 Cable - Dimensions ETAS FETK-T1.1 | User Guide...
FETK UBATT Connector Color Target CON1 Blue purple Gbit Ethernet cable, e.g. CBE260 CON2 White FETK CON3 Black Permanent power supply, K70.1 cable CON4 2 pin ERNI power ECU connector Fig. 7-12 CBAM305.1-2m2 - Connectors ETAS FETK-T1.1 | User Guide...
Gigabit Ethernet and Power Connection cable for FETK. Lemo connectors on both sides compliant to IP65. 3 m length. The CBAE260 cable is a Gigabit Ethernet cable to connect an ETAS ES device with an FETK or another ES device. The cable supports power propagation.
FETK. It is a 1:1 adapter without active components. The ETAM4 covers only the trace specific signals. All other signals a covered by ETAM1 and ETAM2 adapter. 7.9.2 Pin Numbering Fig. 7-18 ECU Adapter ETAM4 (Pin Numbering) ETAS FETK-T1.1 | User Guide...
There are two variants for the ETAM8 adapter available: - ETAM8A hold the ECU in Reset, while the ETK is booting. - ETAM8B do not pull the Reset low while booting. With a ETAM8B adapter the FETK-T1.1 has the same reset behavior like FETK- T1.0. NOTE See chapter "Installation"...
Power Supply Cable ETV5 7.11.1 Usage The ETV5 cable is an open wire power supply cable with one battery and GND con- nection. NOTE For better power integrity cut the cable to the shortest possible length. ETAS FETK-T1.1 | User Guide...
Page 64
0.25 m F 00K 111 701 7.12 ETAM2 Adapter Fig. 7-23 FETK - ECU Adapter ETAM2 NOTE See chapter "Installation" for details on mating connector to the ETAM2. 7.12.1 Pin Assignment Fig. 7-24 ETAM2 Connector ETAS FETK-T1.1 | User Guide...
Page 65
(Supply) Brown Power ground Green CAL_Wakeup Switch to Ubatt. ECU wake-up signal (for mea- surement preparation) SGUBATT2 Car battery SGUBATT1 Car battery 7.12.3 Ordering Product Length Order Number ETAM2 0.25 m F 00K 109 306 ETAS FETK-T1.1 | User Guide...
Page 66
5 mm stripped and Molex tinned Side A Medi cable Side C Side B Position Color Position Position Blue Yellow Brown Green 7.13.2 Ordering Product Length Order Number ETAM5 0.136 m F 00K 110 101 ETAS FETK-T1.1 | User Guide...
Page 67
7.14.3 Temperature Range Condition Temperature Range Operating temperature -40 °C to +110 °C 7.14.4 Order Information Product Length Order Number ETAM9 F/XETK-S ECU Adapter, MOLEX - MOLEX (6fc 0.136 m F 00K-111-043 - 5fc), 0m136 ETAS FETK-T1.1 | User Guide...
Page 68
ETAM10 adapts the ETK power signals (Molex 6 pin connector) to an ECU with a 6 pin Molex PicoSpox connector. The ECU connector is available as Vertical SMT Header [87437-0643] or Right Angle SMT Header [87438-0643]. 7.15.2 Dimensions Fig. 7-28 ETAM10 Adapter Dimensions ETAS FETK-T1.1 | User Guide...
Page 69
7.15.4 Temperature Range Condition Temperature Range Operating temperature -40 °C to +110 °C 7.15.5 Order Information Product Length Order Number ETAM10 F/XETK-S ECU Adapter, MOLEX - MOLEX (6fc 0.07 m F 00K-111-814 - 6fc), 0m07 ETAS FETK-T1.1 | User Guide...
Page 70
- China-RoHS-leaflet_Compact_cn Cable NOTE We recommend to use ETAS cables or any other cables certified by the stan- dards for the application. Adhere to the maximum permissible cable lengths! Please contact your local ETAS representative for further cable information. ETAS FETK-T1.1 | User Guide...
Page 71
ECU Adapter Cable NOTE The hardware for mounting ECU adapter cable CBAM240.1 is not included in the cable delivery, they need to be ordered separately. For detailed information on mounting accessories contact ETAS technical support. Order Name Short Name Order Num- FETK ECU Adapter Cable, pre-assembled into CBAM300.3-...
Page 72
ETAM10 F/XETK-S ECU Adapter, MOLEX - ETAM10 F 00K 111 814 MOLEX (6fc - 6fc), 0m07 Power Supply For special applications ETAS can offer a isolated power supply unit. For detailed information contact ETAS technical support. ETAS FETK-T1.1 | User Guide...
Page 73
73 | Contact Information Contact Information Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: www.etas.com/en/hotlines.php ETAS Headquarters ETAS GmbH Borsigstraße 24...
Page 74
Fig. 4-8 FETK-T1.1 Power Supply wiring with CBAM320.1 Cable ......33 Fig. 4-9 FETK-T1.1 Power Supply wiring with CBAM350.1 Cable .
Need help?
Do you have a question about the FETK-T1.1 and is the answer not in the manual?