Lubrication And Fluid Level Check; Lubrication; Oil Level Check - Zepro ZHD 2500-130 Installation Instructions Manual

Tail lift
Table of Contents

Advertisement

Lubrication and fluid level check
13

Lubrication and fluid level check

The following lubrication points must be greased on installation. They must then be lubricated at least 4
times a year.
13.1

Lubrication

NOTE.
Use LE lubricant 4622 or the equivalent.
1. Right tilt cylinder, at lower bearing.
2. Right lift cylinder, at lower bearing.
3. Lift arm right side, at lower bearing.
4. Left lift cylinder, at lower bearing.
5. Left tilt cylinder, at lower bearing.
6. Lift arm left side, at lower bearing.
7. Left tilt cylinder, at upper bearing.
8. Right tilt cylinder, at upper bearing.
9. Lift arm right side, at upper bearing.
10. Right lift cylinder, at upper bearing.
11. Left lift cylinder, at upper bearing.
12. Lift arm left side, at upper bearing.
13.2

Oil level check

Check the fluid level in the tank during service, top up if necessary. The marking on the hydraulic tank indi-
cates the type of hydraulic fluid used. Mineral hydraulic fluid, product no. 21963 (1 litre), or biodegradable
synthetic fluid, product no. 22235 (1 litre).
www.zepro.com
7
12
11
4
5
Image 68. Lubrication points
6
9
10
ZHD 2500-130/150
8
3
1
2
59