Function diagrams
10.2.1
Restriction in use of control device (Config 3)
90º
10.2.2
Sensor (Config 3)
Name
Di1
Di2
Di3
Di4
Di5
Di6
Cs
2H
www.zepro.com
-10º
90º
B+C+2H Control device 1,2 (Ctrl 1 & 2)
45º
B+C
B+C
B+C
-10º
Image 54. Use of radio control device limited by the platform angle.
-10º
Position
Function
(standard)
Platform
Angle sensor
Lift arm
Angle sensor
Tilt cylinder
Open platform
alarm
Cabin
Activation
Control devices
Two-hand
button
Tilt up/down
Coil (Ctrl 4)
Radio (Ctrl 3 & 6)
Control device 1,2 (Ctrl 1 & 2)
Description
Not used on this lift model and must not be connected.
Non-actuated Di2 disables Tilt up with the secondary control
device so that the operator must use the two-hand button - 2H
along with the primary control device in order to continue to
maintain the tilt up function.
For autotilt, safety function.
Pressure sensor for falling pressure connected to +side of tilt
cylinder. In the actuated state, returns the connection signal
(+) to Di4 and resulting in output signal (-) at Pa-. Also phase
(+) signal out at Pa+.
Not used on this lift model and must not be connected.
Not used on this lift model and must not be connected.
No signal in at Cs results in blocked control device terminals.
Signal to Cs usually comes from the cabin switch. In
individual cases where the cabin switch is not used, the (+)
signal comes in to Cs jumpered from (+) on nearby terminal.
Activated in connection with opening and closing of vehicle
body. Used for Quick opening.