Installation
Spacing
3"
14" max.
_
(76 ram)
(356 m m)
f
18"
(457 ram)
5V2"
(140 mm)
(25 ram)
_Required
spacing
t
48 in?
(310cm_)
24 in?
(155cm_)
(76 ram)
Installation
spacing for recessed
area or closet
The dimensions shown are for the minimum spacing allowed.
[]
Additional
spacing
should
be considered
for ease of installation
and servicing.
[]
Additional
clearances
might
be required
for wall,
door,
and floor
moldings.
[]
Additional
spacing
of 1" (25 mm) on all sides of the dryer
is
recommended
to reduce
noise transfer.
[]
[]
For closet
installation,
with
a door,
minimum
ventilation
openings
in
the top and
bottom
of the door
are required.
Louvered
doors
with
equivalent
ventilation
openings
are acceptable.
Companion
appliance
spacing
should
also be considered.
Mobile
home
= Additional
installation
requirements
This dryer
is suitable
for mobile
home
installations.
The installation
must
conform
to the Manufactured
Home
Construction
and Safety
Standard,
Title
24 CFR, Part 3280
(formerly
the Federal
Standard
for Mobile
Home
Construction
and
Safety,
Title 24,
HUD Part 280)
or the Canadian
Manufactured
Home
Standard
CAN/CSA-Z240
MH.
[]
Metal
exhaust
system
hardware,
available
for purchase.
For further
information,
please
reference
the "Assistance
or Service"
section
of
your
Use and Care Guide.
[]
Special
provisions
must be made
in mobile
homes
to introduce
outside
air
into the dryer.
The opening
(such as a nearby
window)
should
be at least
twice
as large
as the dryer
exhaust
opening.
ELECTRIC DRYER POWER
HOOKUP - CANADA ONLY
E[e@rica[
Requiremen%
Electrical
Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
it is your
responsibility:
[]
To contact
a qualified
electrical
installer.
[]
To be sure that the electrical
connection
is adequate
and
in
conformance
with
the Canadian
Electrical
Code,
C22.1 - latest
edition
and
all local
codes.
A copy
of the above
codes
standard
may
be obtained
from:
Canadian
Standards
Association,
178 Rexdale
Blvd., Toronto,
ON
M9W
1R3 CANADA.
[]
To supply
the required
4 wire,
single
phase,
120/240
volt, 60 Hz.,
AC only electrical
supply
on a separate
30-amp
circuit,
fused
on both
sides of the line. A time-delay
fuse or circuit
breaker
is recommended.
Connect
to an individual
branch
circuit.
[]
This dryer
is equipped
with
a CSA International
Certified
Power Cord
intended
to be plugged
into a standard
14-30R
wall
receptacle.
The
cord
is 5 ft. (1.52 m) in length.
Be sure wall
receptacle
is within
reach
of dryer's
final
location.
A-wire receptacle
(14-30R)
[]
Do not use an extension
cord.
if using a replacement
power
supply
cord,
it is recommended
that
you
use Power Supply
Cord Replacement
Part Number
3394208.
For further
information,
please
reference
the "Assistance
or Service"
section
of your
Use and Care
Guide.
GROUNDING
iNSTRUCTiONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded, in the event of malfunction or
breakdown,
grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor
and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance
with all local codes
and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE