Install Fittings in the Dual POCI Valve
Remove the fittings that were pre-populated in the dual POCI valve (P/N 334-0003-030).
1.
Note:
These fittings are not used in the SmarTrax system installation.
Fittings Installed in the Dual POCI Valve
FIGURE 2.
Fitting - -4 SAE O-Ring (M) Plug
Fitting - -8 ORFS (M) to -8 SAE O-Ring (M) Straight Adapter
Refer to Figure 2 and the table above to install the proper fittings in the dual POCI valve.
2.
Mount the SmarTrax Valve
Valve Mounting Location
FIGURE 3.
Identify the valve mounting location along the left side of the tractor and in front of the cab, on top of the rear
1.
hood mount.
Manual No. 016-5030-017 Rev. A
Fitting
Hydraulic System Installation
Part Number
Port
333-0012-051
PS
A, B, A1
333-0012-168
B1, A2, B2
13