Example for a created process screen

Table C-4
Example for a created process screen
Address
Name
0
DB_HEADER.HEAD.ID
8
DB_HEADER.HEAD.LANGUAGE
14
DB_HEADER.HEAD.AMOUNTOBJ
16 to 31
DB_HEADER.HEAD.Reserved[..]
32
SCREEN[0].PIC_.INFO.INFO
33
SCREEN[0].PIC_INFO.STARTUP
34
SCREEN[0].PIC_INFO.Reserved
35
SCREEN[0].PIC_INFO.PASSLEVEL
36
SCREEN[0].PIC_INFO.PICNAME
52
SCREEN[0].PIC_STATIC[1]
74
SCREEN[0].PIC_STATIC[2]
96
SCREEN[0].PIC_STATIC[3]
118
SCREEN[0].PIC_STATIC[4]
140
SCREEN[0].PIC_VAR[1].POSITION
141
SCREEN[0].PIC_VAR[1].
DECIMALS_LENGTH
142.0
SCREEN[0].PIC_VAR[1].
FIELDTYPE
142.1
142.2
SCREEN[0].PIC_VAR[1].
ATTRIBUTE
142.3
142.4
SCREEN[0].PIC_VAR[1].
142.5
TARGETFORMAT
142.6
142.7
SCREEN[0].PIC_VAR[1].LIMON
143
SCREEN[0].PIC_VAR[1].
AREACODE
144
SCREEN[0].PIC_VAR[1].BLOCKNO
146
SCREEN[0].PIC_VAR[1].BYTENO
C-8
Type
Actual Value
STRING[6]
"SCREEN"
STRING[3]
"GER"
BYTE
1
INT
0
BYTE
0
BYTE
0
BYTE
0
BYTE
1
STRING[14]
"Screen 0"
"Tank 1"
STRING[20]
1
STRING[20] "Temperature"
2
STRING[20]
"DEGREE"
3
STRING[20]
" "
BYTE
2A (hex)
4
BYTE
15 (hex)
5
6
BOOL
10
7
BOOL
00
8
BOOL
000
9
BOOL
0
10
CHAR
D
11
INT
20
12
INT
30
13
Description
Block ID
Language ID
Number of objects
Reserved
Reserved
Not an initial screen
Reserved
Password level 1
Name of screen
First line of Screen0
Second line of Screen
0
Third line of Screen 0
Fourth line of Screen 0
Position of variable
within the screen
(second position in
third line)
Length of field= 5;
number of decimal
places=1
Field type: Input field
Type of representation:
Standard
Representational
format: Decimal
0=Limit check switched
off
Memory area
"D"=Data block
Block number
20
Offset address
Byte 30
C7-613 Control System
A5E00138934-03