System Messages

Overview
System messages display internal operating states of the C7-613. They indicate
maloperations or malfunctions, for example.
Display of System Messages
This type of message has the highest display priority (see Section 5.8). If a
corresponding fault occurs in the C7-613, the object that is currently displayed is
removed, and a system message is output instead. If fault messages occur while a
system message is being output, they are displayed immediately after the system
message is output.
Errors generate a system message in the case of input errors, for example.
The display of a system message is removed automatically after 2 s. In the case of
operations that take long, such as saving the event buffer, the message is
removed after the function is completed.
A list of possible system messages and a description is provided in Appendix B.2
System message $ 002
The text for the system message $ 002 "Configuration running" can be edited
freely in any language selected by you by using the configuration interface. This
means that you can have your individual text shown on the display while the
C7-613 is being booted.
C7-613 Control System
A5E00138934-03
Operating the C7-613
5-21