Siemens SIMATIC C7-613 Manual page 73

Table of Contents

Advertisement

4.3.9
Creating Info Texts
Info texts are created by using the configuration interface.
Each info text consists of 4 lines with 20 characters each (10 graphical symbols for
Chinese, Japanese and Korean).
An info text can be assigned to one or more screens.
An info text is configured when at least one character has been edited in the static
text.
You can specify the following parameters for each info text:
• Info text number (0 to 127)
• Name of info text
• Contents of the info text lines 1 to 4
• Assignment of the cursor keys to a previous/following info text
The description of the info texts is stored in the "INFO" DB through the
configuration interface.
4.3.10
Creating a Screen hierarchy
The screen hierarchy is created by your using the configuration interface to specify
for each screen was which created beforehand by you which subsequent screens
or info texts are to be called up by using the F1 to F4 softkeys or the cursor keys
and how individual info texts are interlinked via the cursor keys.
You can configure the following alternatives:
Starting screen
Any process screen
Any process screen
Any info text
It is not possible to configure a return from info texts to process screens:
Starting screen
Any info text
The description of the screen hierarchy is stored by the configuration interface in
the "MENU" DB and is identical for all the selected languages (maximum of 5).
C7-613 Control System
A5E00138934-03
Integration into the User Program
Transition to ...
Any process screen or
special screen
Any info text
Any info text
Return transition to ...
The process screen from
which the info text was
called
By using ...
F1, F2, F3, F4, or one of the
4 cursor keys
F1, F2, F3, F4, or one of the
4 cursor keys
By using ...
ESC
4-17