Process and system messages, error handling

11.1

Central Interface Module (CIM)

The device has 3 LEDs on the front: The LEDs shows information about the operating state
of the device or system.
Meaning of LEDs
READY
green
Causes of error and possible solutions
Error code
5102
5103
510D
SIPLUS HCS4300 PROFINET/PROFIBUS DP
Operating Instructions, 10/2019, A5E35452705A/005
HEATING
ERROR
Description
ON
red
yellow
Power OFF, device switched off
Initialization: The LED flashes until the HCS is detected and
accepted as a bus node by the higher-level control system.
Note
If a defective configuration is loaded for re-configuration, this
culminates in the error display green=on and red=on.
Device has started up and is ready.
Heating "ON"
A general error has occurred:
Description
Line voltage is outside the permissible
range. The error message applies to
the values of PM4000 U/I and of POMs
with their own voltage measurement.
Frequency is outside the permissible
range. The error message can be initi-
ated by any POM.
Communication fault internal
Fieldbus communication error
Error in HCS communication
Possible causes and solutions
Check voltage supply and cabling
Connect the missing voltage
Check connecting cable for system
interface
11
145