Installing The Stator - HBM T10FM Mounting Instructions

Hide thumbs Also See for T10FM:
Table of Contents

Advertisement

18
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com
CAUTION
With alternating loads, use screw locking device to glue into place the
connection screws. Guard against contamination from varnish frag-
ments.
It is essential to keep to the maximum thread reach as specified in
Table 4.1 ! Otherwise torque shunt may cause extensive measurement
errors or the transducer may be damaged.
Measuring
Fastening
range
screws (Z)
(NVm)
15
20
M20 x 2.5
25
30
40
M20 x 2.5
45
50
60
M22 x 2.5
70
80
Table 4.1: Fastening screws
1)
DIN EN ISO 4762; black/oiled/m

4.6 Installing the stator

On delivery, the stator has already been installed and is ready for operation.
The antenna segments can be separated from the stator, for example, for
maintenance or to facilitate stator mounting. To stop you modifying the center
alignment of the segment rings opposite the base of the stator, we recom-
mend that you separate only one antenna segment from the stator.
If your application does not require stator disassembly, proceed as described
in sections 2., 6., 7. and 8.
HBM
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
Fastening screws
1)
Resistance class
10.9
=0.125
tot
Maximum thread reach
(Y) of screws in flange
B
(mm)
30
40
45
T10FM
Prescribed
tightening torque
(NVm)
400
560
760
B 23.T10FM.10 en