Aligning The Stator (Speed Measuring System) - HBM T10FM Mounting Instructions

Hide thumbs Also See for T10FM:
Table of Contents

Advertisement

23
T10FM
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com

4.9 Aligning the stator (speed measuring system)

The stator can be mounted in any position (for example, "upside down" instal-
lation is possible).
For measuring mode to operate perfectly, the slotted disc of the speed measu-
ring system must rotate at a defined position in the optical sensor.
Axial alignment
There is a marker in the optical sensor for axial alignment (orientation line).
When installed, the slotted disc should be exactly above this orientation line.
Deviations of up to "2 mm are permissible in measuring mode (total of static
and dynamic shift).
Slotted disc
Orientation lines
Fig. 4.9: Position of the slotted disc in the speed sensor
NOTE
To attach the stator, we recommend the use of M6 screws with plain
washers (width of oblong hole, 9 mm). This size of screw guarantees the
necessary travel for alignment.
B 23.T10FM.10 en
HBM
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com