Voltage Parameters
The following parameters can be measured automatically:
1.
Vmax: Voltage at the highest point with respect to GND
2.
Vmin: Voltage at the lowest point with respect to GND
3.
Vtop: Highest stable voltage
4.
Vbase: Lowest stable voltage
5.
Middle: Midpoint between highest and lowest stable voltage
6.
Vpp: Vmax – Vmin
7.
Vamp: Vtop – Vbase
8.
Mean: Average amplitude of the waveform on screen
9.
CycMean: Average amplitude of a waveform in one period
10. RMS: The effective value. According to the energy produced by the AC signal in
the conversion, the equivalent energy that the DC voltage corresponds to
11. CycRMS: The RMS of one period
12. Overshoot: The ratio of the difference between Vmax and Vtop
13. Preshoot: The ratio of the difference between Vmin and Vbase
14. Area: The product of time and voltage for all points on the screen
15. CycArea: The product of time and voltage for all points in one period

Timing Parameters

The following parameters can be measured automatically:
1.
Period: The duration of one cycle of a repetitive waveform
2.
Frequency: The reciprocal of the period
3.
Rise time: The time it takes the waveform amplitude to increase from 10% to 90%
4.
Fall time: The time it takes the waveform amplitude to decrease from 90% to 10%
5.
+Width: The width of a positive pulse at 50% amplitude
6.
-Width: The width of a negative pulse at 50% amplitude
7.
+Duty: The ratio of positive pulse width to period
8.
-Duty: The ratio of negative pulse width to period
Delay Parameters
The following parameters can be measured automatically:
1.
FRR: Time between the first rising edge of source 1 to the first rising edge of source 2
2.
FRF: Time between the first rising edge of source 1 to the first falling edge of source 2
3.
FFR: Time between the first falling edge of source 1 to the first rising edge of source 2
4.
FFF: Time between the first falling edge of source 1 to the first falling edge of source 2
5.
LRF: Time between the last rising edge of source 1 to the last falling edge of source 2
6.
LFR: Time between the last falling edge of source 1 to the last rising edge of source 2
7.
LFF: Time between the last falling edge of source 1 to the last falling edge of source 2
8.
LRR: Time between the last rising edge of source 1 to the last rising edge of source 2