Separating Protective Equipment; Safety Check - Optimum Optimill BF 30V Operating Manual

Drilling-milling machine
Table of Contents

Advertisement

OPTIMUM
M A S C H I N E N - G E R M A N Y

1.9.4 Separating protective equipment

Adjust the protective equipment to the
correct height before you start working.
To do so, detach the clamping screw,
adjust the required height and re-tighten
the clamping screw.
A switch is integrated in the fixture of the
spindle protection which monitors that
the cover is closed.
INFORMATION
You cannot start the machine if the spin-
dle protection is not closed.
1.10

Safety check

Check the drilling-milling machine in regular intervals.
Check all safety devices
before each operation,
once a week (with the machine in operation),
after every maintenance and repair work.
General check
Equipment
Protective covers
Signs,
Markings
Functional check
Equipment
EMERGENCY STOP impact
switch
Separating safety device
around the drilling and mill-
ing spindle
GB
BF30Vario
Page 14
Clamping screw
Check
Mounted, firmly bolted and not damaged
Installed and legible
Check
When the EMERGENCY-STOP button is activated, the drilling-milling
machine should switch off. Make sure that it is only possible to restart
the machine if the EMERGENCY STOP push button is unlocked and the
ON switch was activated.
The drilling-milling machine may switch on only when the safety device
is closed.
Original operating instructions
Img.1-5:
Separating protective equipment
Version 1.1.5 dated 2015-08-31
OK
OK
Safety

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents