Specifications; Net O Range; Combustibles; Accuracy - Emerson Rosemount OCX 8800 Reference Manual

Oxygen and combustibles transmitter
Hide thumbs Also See for Rosemount OCX 8800:
Table of Contents

Advertisement

1.3

Specifications

1.
Note
All static performance characteristics are with operating variables constant. Specifications subject to
change without notice.
1.3.1
Net O
0-1% to 0-40% O
1.3.2

Combustibles

0-1,000 ppm to 0-5%, fully field selectable
1.3.3

Accuracy

Oxygen
±0.75% of reading or 0.5% O
Combustibles
±2% range
1.3.4

System response to test gas

Oxygen
10 sec T90
Combustibles
25 sec T90
1.3.5

Temperature limits

Process
0 to 1427 °C (32 to 2600 °F)
Reference Manual
Requires XPS transmitter, P/N 6A00358G03
range
2
, fully field selectable
2
(whichever is greater)
2
Description and specifications
11

Advertisement

Table of Contents
loading