8. Installation

8.1. Safety instructions

DANGER!
Mains voltage
Risk of serious or even fatal injury from electric shock when coming into contact with non-insulated,
powered components.
Actions:
For the electrical installation of the device, adhere to all applicable regulations (e.g. VDE 0100).
All electrical work must only be carried out by authorised and *skilled technical personnel.
For the connection of the power mains and the installation of suitable safety devices, strictly adhere to all statutory
regulations that apply at the location of installation of the METPOINT
established by suitably skilled technical personnel.
Make sure that no parts of the measuring devices are energized and that the measuring devices cannot be connected to
the electric supply mains while maintenance work is in progress.
DANGER!
Operation without earth connection!
If there is a fault but no earth connection (protective earth), conductive components might become
energised, posing a risk of serious or even fatal injury.
The device must therefore be connected to an earth conductor.
Do not use plug adapters at the power plug.
If required, have the power plug replaced by a qualified electrician.
DANGER!
Operation without circuit breaker!
All components that are powered and exposed must be disconnectable by means of dedicated
external circuit breakers.
The circuit breaker must be installed in the vicinity of the device.
The circuit breaker must conform to IEC 60947-1 and IEC 60947-3.
The circuit breaker must disconnect all electrical conductors from the mains power supply.
The circuit breaker must not be installed in the power supply line.
The circuit breaker must at all times be easily accessible to operating personnel.
To disconnect the device from the power mains, pull the plug from the socket. Ensure that the power plug is clearly
identified and easily accessible by operating personnel. The plug must conform to CEE7/7.
All electrical cables carrying supply voltage or other dangerous voltage (main supply cable, alarm cable, signalling relays)
must be equipped with double or reinforced insulation (EN 61010-1). This can be achieved by using plastic-sheathed cables,
a second insulation (e.g. flexible insulating tubing), or cables with reinforced insulation.
The power cables can for example be protected with flexible insulating tubing. The additional flexible insulating tubing must 
withstand the electrical and mechanical stresses that are likely to occur in connection with the intended use
(see EN 61010-1, section 6.7.2.2.1).
*Skilled technical personnel
Skilled technical personnel are persons who, due to their professional qualification and knowledge in the field of measuring, 
control and pneumatic technology, and their knowledge of the applicable statutory regulations, guidelines and standards
are in a position to foresee potential dangers in relation to the use of the device and who are qualified to perform the tasks 
described in this manual.
Special operating conditions (e.g. aggressive media) require additional knowledge.