Example: Calculation Of "Specific Performance - Beko METPOINT BDL compact Installation And Operating Manual

Hide thumbs Also See for METPOINT BDL compact:
Table of Contents

Advertisement

Installation and operating manual
EN

11.2.7.6. Example: calculation of "specific performance"

This example is based on a compressor plant with 3 compressors.
The consumption is measured with an FS109 consumption probe at inputs A1 - B1, and an electricity meter at input B2.
The total consumptions for air and energy, and the "specific performance" of the entire plant are calculated.