Minimum Three-Wire Interface With Software Protocol - Agilent Technologies HP 16500B Manual

Logic analysis system
Hide thumbs Also See for HP 16500B:
Table of Contents

Advertisement

Programming Over RS-232C

Minimum Three-Wire Interface with Software Protocol

Minimum Three-Wire Interface with Software Protocol
With a three-wire interface, the software (as compared to interface
hardware) controls the data flow between the logic analysis system and the
controller. The three-wire interface provides no hardware means to control
data flow between the controller and the logic analysis system. Therefore,
XON/OFF protocol is the only means to control this data flow. The
three-wire interface provides a much simpler connection between devices
since you can ignore hardware handshake requirements.
The communications software you are using in your computer/controller must
be capable of using XON/XOFF exclusively in order to use three-wire interface
cables. For example, some communications software packages can use
XON/XOFF but are also dependent on the CTS, and DSR lines being true to
communicate.
The logic analysis system uses the following connections on its RS-232C
interface for three-wire communication:
Pin 7 SGND (Signal Ground)
Pin 2 TD (Transmit Data from logic analysis system)
Pin 3 RD (Receive Data into logic analysis system)
The TD (Transmit Data) line from the logic analysis system must connect to
the RD (Receive Data) line on the controller. Likewise, the RD line from the
logic analysis system must connect to the TD line on the controller. Internal
pull-up resistors in the logic analysis system assure the DCD, DSR, and CTS
lines remain high when you are using a three-wire interface.