Chapter 3 - Installation
Adept SmartVision EX
Attach shield from user-supplied
cable to Adept SmartVision EX using
star washer and M3 x 6 screw

Chassis Grounding

The Adept SmartVision EX is equipped with a grounding point. See the following figure. Adept
recommends connecting a ground wire from the ground point on the Adept SmartVision EX to
earth ground, and that all other interconnected Adept components share the same electrical
ground potential. The ground wire must meet all local regulations. Additional grounding
information for other Adept products is provided in the documentation for those products.
NOTE: The maximum length for the ground wire for the Adept SmartVision EX is
3 meters.
In Europe, the mounting and all terminations of the Adept SmartVision EX must be performed in
accordance with European Standard EN 60204, Safety of machinery – Electrical equipment of machines,
to maintain compliance.
28
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Note: Use connector
supplied by Adept at
this end of cable
(Weidmuller 1615780000
and 1606640000)
+
-
User-supplied Shielded
Power Cable

Figure 3-6. User-Supplied Power Cable

Grounding Point

Figure 3-7. Chassis Grounding Point

Adept SmartVision EX User's Guide, Rev B
User-supplied
Power Supply
(24 VDC, 6 A)
Optional
Frame Ground
Fuse
Circuit
+
protection
-
< 8 A
Attach shield from user-
supplied cable to frame
ground on power supply