Installing 24 VDC Connectors

Use the Adept-supplied connectors to connect the user-supplied 24 VDC power supply to the
Adept SmartVision EX.
1. Locate the 24 VDC connector that is shipped with the Adept SmartVision EX. See the
following figure.
Use 14 or 16 gauge wire to connect the 24 VDC power supply to the Adept SmartVision
EX.
2. Strip 7 mm of insulation from the end of the wire that connects to the positive output of
the 24 VDC supply.
3. Insert the stripped end of the wire into the opening on the right side of the connector.
4. Repeat this process to connect the wire from the negative side of the power supply to the
left side of the connector.
5. Using a small, flat-blade screwdriver (2.5 mm), tighten the screw clamps on the connector.
6. Visually inspect the connection to ensure that the clamp has closed on the wire, not on the
insulation.
7. Gently pull on the wire to confirm that it is securely attached to the connector.
8. Connect the braided shield to the ground screw on the front panel. A ring lug can be used,
as shown in the following figure.

Figure 3-5. 24 VDC Connector, with Shield Attached to Ground

NOTE: Although no damage will occur, the Adept SmartVision EX will not turn
on if the DC polarities of the VDC connectors are reversed.