Peripheral equipment

Molded-case circuit breakers, fuses, magnetic contactors
■When connecting one simple converter and one servo amplifier
Model
Molded-case circuit breaker
Frame, rated current
Power factor
improving reactor is
not used
MR-CM3K
30 A frame 30A
■When connecting one simple converter and multiple servo amplifiers
Circuit breakers, semiconductor fuses, or motor circuit breakers (Type E combination motor controllers) that match the sum of
the rated capacities [kW] of the multiple connected amplifiers can be used. The selection condition is as follows. When using
a multi-axis servo amplifier, calculate the sum of the rated capacities of all axes as the rated capacity of the servo amplifier.
The sum of rated capacities of connected servo amplifiers [kW] ≤ 3 kW (MR-CM3K rated output)
Model
Capacity
Molded-case circuit breaker
Frame, rated current
Mitsubishi Electric: NF125-SVU
MR-
Less than 2
125 A frame 15A
CM3K
kW
2 kW or
125 A frame 20A
more
Motor circuit breaker (Type E combination motor controller)
Voltage
Sum of rated capacities of
servo amplifiers [kW]
200 V
100 W
system
200 W or less
400 W or less
600 W or less
750 W or less
1 kW or less
2 kW or less
Over 2 kW
Power factor improving AC reactor
Simple converter
MR-CM3K
EMC filter
For selection of EMC filters, refer to the following and the EMC Installation Guidelines.
Page 228 EMC filter (recommended)
Voltage
AC [V]
Power factor
improving reactor is
used
30 A frame 30A
240
Voltage
AC [V]
240
240
Input
Input
Motor circuit breaker (Type E combination
rating
phase
motor controller)
[Vac]
Model
200 to 240
3-phase
MMP-T32
Power factor improving AC reactor
FR-HAL-7.5K
Fuse
Class
Current
Voltage
[A]
AC [V]
T
40
300
Semiconductor fuse (700 V)
BUSSMANN: 170M series
170M1409 (16 A)
170M1413 (40 A)
Rating [Vac]
Rated current
[A]
(heater design)
240
1.6
2.5
4
6.3
6.3
8
18
25
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.3 MR-CM simple converter
Magnetic
contactor
S-T21
6
Magnetic
contactor
S-T21
S-T21
SCCR
[kA]
50
25
181